Hi-Force HEP310222 Manual de instrucciones - Página 13

Navegue en línea o descargue pdf Manual de instrucciones para Bomba de agua Hi-Force HEP310222. Hi-Force HEP310222 20 páginas. Electric driven pumps, general duty, medium/high flow

Hi-Force HEP310222 Manual de instrucciones
6.3 Pumps with Solenoid Valves
1. Set the adjustable pressure relief valve (8) if required. See section 6.1 for details.
2. With all hydraulic connections and electrical connection made and turn the motor on by pressing the
green 'ON' button (13).
3. Press and hold the 'advance' button on the pendant to advance the cylinder/tool. Release the button
once the cylinder/tool has been advanced the desired amount. The cylinder/tool will remain in the
load holding position when the button is released.
4. Press and hold the 'retract' button to retract the cylinder/tool. Release the button once the
cylinder/tool has been retracted.
IMPORTANT:
ALWAYS fully retract the cylinder/tool at the end a job/operation, before any disconnections
are made.
Inspect the pump for damage after each use.
Change the oil every 500 working hours using high quality ISO46 hydraulic oil.
Zero the pump pressure before storing.
Have the pump serviced regularly by a Hi-Force authorised repair centre.
Operating Instruction Manual:

7.0 Maintenance and Storage

13
OM-HEP2/3-01
From Serial Number:
BQ3323