Hi-Force tools will use 1 of 2 grades of oil, dependant on the pump used. The tools are designed to operate
at temperatures between -20°C and 80°C. Details of the oil used can be found in the chosen Hi-Force
pump's operating manual, in the section: FILLING THE PUMP WITH OIL.
Hi-Force
Model Number
HFO15
HFO46
Refer to the engraved detail on the cylinder for model identification.
HVL │ SINGLE-ACTING, VERY LOW HEIGHT PANCAKE CYLINDERS
Model
Number
HVL10
HVL20
HVL30
HVL50
HVL100
(Refer to the Hi-Force website or latest Hi-Force catalogue for further details)
High-Pressure Hydraulic Hoses
Manifolds and Manifold Assemblies.
Flow Control Valve
Pressure Gauges and Gauge Mounting Blocks
High-Pressure Couplers and Fittings

8.0 Specifications

8.1 Oil Specifications
ISO Hydraulic Oil Grade
ISO15
ISO46
8.2 HVL Specifications
Capacity
Stroke
(tonnes)
(mm)
10
20
32
50
104

9.0 System Components / Accessories

Operating Instruction Manual:
OM-HVL-01
Temperature Range: Degrees Celcius (°C)
From:
Oil Capacity
3
(cm
)
6
9
6
17
6
27
6
43
6
88
11
Serial Numbers:
From: AF0324
-23
-2
Cylinder eff.
Area
2
(cm
)
14.4
28.6
45.6
71.3
146.5
To:
44
73
Weight
(kg)
1.6
2.6
3.0
7.2
15.6