Gaggenau Vario 400 Series Dimensiones de corte - Página 2
Navegue en línea o descargue pdf Dimensiones de corte para Placa de cocción Gaggenau Vario 400 Series. Gaggenau Vario 400 Series 4 páginas. Downdraft ventilation
También para Gaggenau Vario 400 Series: Manual de inicio rápido (2 páginas), Manual (7 páginas), Instalación (2 páginas)
Cut-out dimensions for Vario 400 series combinations. Flush installation.
The drawings listed below show the cut-out dimensions for Vario 400 series appliance combinations for a
While taking into consideration the previous page and the drawings specified below, the installer can define the suitable cut-out
dimensions. The combinations listed here are only sample combinations.
The connection strip VA 420 000 must be provided for flush mounted combinations.
If installing with the VA 440 appliance cover or VA 450 filler strip, take into account the additional space required for the depth. Further-
more, you must ensure that there is an asymmetrical alignment in the cut-out depth.
Sample combinations without VL 414 ventilation element:
15 ¹³⁄₁₆"
±¹⁄₁₆"
( 386
)
±2
14 ³⁄₁₆"
±¹⁄₁₆"
( 360
)
±2
14 ¹⁵⁄₁₆"
( 380 )
45 ⅜"
±¹⁄₁₆"
( 1152
)
±2
44 ⁵⁄₁₆"
±¹⁄₁₆"
( 1126
)
±2
14 ¹⁵⁄₁₆"
14 ¹⁵⁄₁₆"
( 380 )
( 380 )
⅛"
⅛"
( 3 )
( 3 )
47"
±¹⁄₁₆"
( 1193
)
±2
45 ¹⁵⁄₁₆"
±¹⁄₁₆"
( 1167
)
±2
14 ¹⁵⁄₁₆"
31 ⅝"
( 380 )
( 804 )
⅛"
( 3 )
51 ¹⁄₁₆"
±¹⁄₁₆"
( 1297
)
±2
50 ¹⁄₁₆"
±¹⁄₁₆"
( 1271
)
±2
14 ¹⁵⁄₁₆"
35 ¾"
( 380 )
( 908 )
⅛"
( 3 )
Without cover
¹¹⁄₁₆"
( 17 )
19 ⅜"
±¹⁄₁₆"
( 492
)
±2
¹¹⁄₁₆"
( 17 )
14 ¹⁵⁄₁₆"
( 380 )
With cover
20 ½"
20 ¹¹⁄₁₆"
( 520 )
( 526
)
±2
( 380 )
14 ¹⁵⁄₁₆"
( 3 )
⅛"
( 380 )
14 ¹⁵⁄₁₆"
( 3 )
⅛"
( 380 )
14 ¹⁵⁄₁₆"
( 1146 )
45 ¹⁄₁₆"
- ( 20 )
- ⁶⁄₈"
44 ⁵⁄₁₆"
( 1126
)
±¹⁄₁₆"
±2
+ ( 20 )
+ ⁶⁄₈"
+ ( 6 )
+ ¼"
( 1152
)
45 ⅜"
±¹⁄₁₆"
±2
( 380 )
14 ¹⁵⁄₁₆"
( 3 )
⅛"
( 804 )
31 ⅝"
( 1187 )
46 ¾"
- ⁶⁄₈"
- ( 20 )
( 1167
)
45 ¹⁵⁄₁₆"
±¹⁄₁₆"
±2
+ ( 20 )
+ ⁶⁄₈"
+ ( 6 )
+ ¼"
( 1193
)
47"
±¹⁄₁₆"
±2
( 380 )
14 ¹⁵⁄₁₆"
( 3 )
⅛"
( 908 )
35 ¾"
( 1291 )
50 ¹³⁄₁₆"
- ( 20 )
- ⁶⁄₈"
( 1271
)
50 ¹⁄₁₆"
±¹⁄₁₆"
±2
+ ( 20 )
+ ⁶⁄₈"
+ ( 6 )
+ ¼"
( 1297
)
51 ¹⁄₁₆"
±¹⁄₁₆"
±2
Numbers indicated
inside parenthesis (
flush
mounting.
⁵⁄₁₆"
( 8 )
20 ¼"
21 ¹¹⁄₁₆"
( 515
)
( 535 )
±2
¹¹⁄₁₆"
( 18 )
Appliance
Connection strip VA 420
Appliance
Connection strip VA 420
Appliance
Overhang
Cutout
Overhang
Silicone joint
Cutout with groove
Appliance
Connection strip VA 420
Appliance
Overhang
Cutout
Overhang
Silicone joint
Cutout with groove
Appliance
Connection strip VA 420
Appliance (36" cooktop)
Overhang
Cutout
Overhang
Silicone joint
Cutout with groove
www.gaggenau.com/us
Revised: 31 March 2020
) = mm
21 ⁵⁄₁₆"
( 541
)
±2