ADELSYSTEM DPY351 Manual de instrucciones - Página 5

Navegue en línea o descargue pdf Manual de instrucciones para UPS ADELSYSTEM DPY351. ADELSYSTEM DPY351 5 páginas.

ADELSYSTEM DPY351 Manual de instrucciones
6.3.2
CAN Communication
Aux3:
Supported Protocols
Supported Baud Rate
(Factory setting: xxxxxx)
Internal Terminating Resistor (120
Ω)
(Factory Setting OFF)
6.4
Ambient Conditions
Ambient Temperature operation
Ambient Temperature Storage
Humidity at 25 °C, no condensation 95 % to 25 °C
Vibration (operation) IEC 60068-2-
6
Shock IEC 60068-2-6
6.5
General Data
Protection Class (EN/IEC 60529)
Reliability: MTBF IEC 61709
Aux5 Connection Terminal Blocks
Push Button Type
Protection class
Housing material
Dimension (w-h-d) mm
Weight
Hole
Available Languages
Automatic Power ON
6.6
Accessory
Connector Cable RJ45/RJ45 1m
for CBI Size 4
Connector Cable RJ45/RJ45 1m
for CBI (Device Size 3)
RJTEMP111 or 113
Shunt 50 (for Device Size 3)
6.7
Hardware Port
6.7.1
Digital Input ports "Aux5"
Input:
Application Pins
Minimum Voltage for Low Level:
Minimum Voltage for High Level:
7.1 Annex 1: Mounting template
RJ45
J1939
Raw CAN
Can Open
50 Kbit/s, 100 Kbit/s, 125
Kbit/s, 250 Kbit/s, 500 Kbit/s,
800 Kbit/s, 1 Mbit/s,
Configurable by Switch Aux6
(Section: Hardware
configurations Can)
-25 up to +70 °C
-40 up to +85 °C
<15 Hz, amplitude 
2.5mm<15Hz-150Hz, 2.3G 90
min.
30g in all directions
Front panel only IP65; Rear
IP22
> 700.000 h (Automatically
Switch Off Beck Light after 30
sec)
Wire diameter Ø: 0.05 mm
(30AWG) - 1.5 mm (14AWG)
II
Polycarbonate
112 x 117 x 52
0.35 kg approx.
90 mm
English
Deep Switch 4 ON (Aux6)
RJCONN45
DPYCONN500
Temp. Environment Sensor
Measure the Load current
N° 2
Pins 3,4
0-72 V, user-configurable
0-72 V, user-configurable
6.7.2
Analog Input ports "Aux5"
Input:
Application Pin
For Shunt connection
6.7.3
Output port "Aux5"
Output
Application Pin
Output Type
Max. current can be switched (EN60947.4.1):
Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A (Resistive Load)
Min.1mA at 5 Vdc (Min. Load)
6.8
Software Port
6.8.1
Remote Monitoring "Ethernet Connection"
IP (Static)
User
PW
6.8.2
Web Server
User friendly operation trough monitoring and configuration on one
page
Independent identification of individual modules, a system
configuration it is not necessary
Integrated access management: access can be individually
determined locally and centrally
Integrated data storage, each modification and each error can be
recorded
6.9
Norms and certifications
6.9.1
Immunity and Emission
The CE mark in conformity to EMC 2014/30/EU: Electromagnetic Compatibility
Directive; 2014/35/EU: Low Voltage Directive; ROHS 2011/65/EU: Restriction
of the use of certain Hazardous Substances in Electrical and Electronic
Equipment (RoHS), as amended by 2015/863/EU
EMC Immunity: EN61000-6-2
EMC Emission: EN61000-6-3
6.10
Electrical Safety for mounting
According to:
Electrical Equipment for Machinery EN 60204
Electrical safety (of information technology equipment) IEC/EN
EN62368-1.
Safety requirements for electrical equipment for measurement,
control and Laboratory use IEC/EN 61010
6.10.1
Environmental Norm Conditions
Degrees of protection provided by enclosures IEC/EN 60529
IP65:
First Digit: Protection against ingress of durst (durst
o
tight). Complete protection against contact.
Second Digit: Protection against water projected from a
o
nozzle against the equipment (enclosure) from any
direction. There must be no harmful effect (water jet)
Environmental Testing IEC/EN 60068
N° 1
Pins 5,6
50 A
N° 1
Pins 7,8
Dry Contact (NO)
192.168.1.100
admin
admin
Instruction Manual DPY351_R11
Page 5