Hi-Link HLK-B20 Manual del usuario - Página 6
Navegue en línea o descargue pdf Manual del usuario para Unidad de control Hi-Link HLK-B20. Hi-Link HLK-B20 17 páginas. Ble 4.2 wireless module
.
14
P33
15
GND
16
P02
17
P03
18
P04
19
P05
20
P06
21
P01
22
P00
3. Test board description
The test board is mainly used to test the data transmission function of the HLK-B20's Bluetooth and
serial ports.
RST
USB to serial
port
ES0
3.1. Restore factory settings
To ensure that all configuration procedures are correct, first reset the module to factory settings.
Modules that are already in factory mode can skip this step. Provide 5V (1000mA) power supply to
power on the module, wait for about 1 second, let the module start up. After the startup is completed,
pull down the ES0 (PIN5) pin for more than 6S. When the LED corresponding to the STA is always
on, it means that the module is restored the factory settings successfully, then release the ES0 pin,
the system will automatically restart. The system is already in factory mode after rebooting.
HLK-B20
Shenzhen Hi-Link Electronic Co., Ltd.
I/O
P33
P
GND
I/O
P02,SCL
I/O
P03,SDA
I/O
P04,SPI_CLK
I/O
P05,SPI_MOSI
I/O
P06,SPI_MISO
I/O
Uart1_rxd
I/O
Uart1_txd
HLK-B20 module test board
Figure 3
GPIO
GND
GPIO,I2C
GPIO,I2C
GPIO,SPI
GPIO,SPI
GPIO,SPI
Uart1, Transparent transmission serial
port
Uart1, Transparent transmission serial
port
HLK-B20
Manual