ADEMCO 4110XM Manual de instrucciones de instalación - Página 19
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Sistema de seguridad ADEMCO 4110XM. ADEMCO 4110XM 20 páginas.
GEL LEAD ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
BLACK
–
CHARGING
BATTERY
VOLTAGE
+
RED
12V, 4AH
13.8VDC
OR 12V, 1.2AH
CONNECTOR TABS
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.
USE UL LISTED
LIMITED ENERGY
1
2
3
CABLE FOR ALL
CONNECTIONS
FOR COMPLETE
INFORMATION, SEE
INSTRUCTIONS
N5478V4
TO 110VAC
UNSWITCHED
OUTLET (24HR)
PLUG-IN TRANS-
FORMER
16.5VAC, 25VA
(e.g. ADEMCO
No. 1321/TF2.
USE No. 1321CN
IN CANADA
+
–
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE ADEMCO
No. 702 OR 719 SIREN, OR 12V BELL)
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION
SHALL BE PERMITTED ONLY WITH THE PERMISSION
OF THE LOCAL AUTHORITY HAVING JURISDICTION.
THE BURGLAR ALARM SIGNAL SHALL NOT BE CON-
NECTED TO A POLICE EMERGENCY NUMBER.
FUSE
FOR REPLACEMENT,
USE SAME VALUE
3A
BATTERY
(e.g. No. 90-12)
No. 4116
ARMING/DISARMING
KEYSWITCH
(SINGLE LED, LOCKSWITCH,
+
–
TAMPER)
BLK
RED
GRN
YEL
4
5
6
7
8
+
–
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
KEYPAD
CURRENT MUST
BE INCLUDED IN
AUX. CURRENT
DRAIN
CALCULATIONS
1000
OHMS
EOLR
REMOTE
• MAXIMUM LOOP RESISTANCE (EACH ZONE) 300 OHMS (PLUS EOLR)
KEYPAD
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR FAST RESPONSE TO AN
No. 4127:
20mA
OPEN: 10MSEC MAX
No. 4137AD: 60mA
• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE. SEE DIAGRAM
No. 6127:
20mA
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION
No. 6128:
30mA
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
No. 6137:
85mA
CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER-
OR
FERENCE THAT MAY CAUSE UNDESIRED OPERATION.
No. 5330:
105mA
NOTE: MULTIPLE KEYPADS MAY BE
USED, BUT EACH 5330 KEYPAD
MUST BE ON AN INDIVIDUAL HOME
WARNING:
RUN. USE MAX. OF 220FT. OF #22
WIRE OR 550 FT. OF #18 WIRE.
OWNER'S INSTRUCTION NOTICE NOT TO BE
REMOVED. WEEKLY TESTING IS REQUIRED TO
ENSURE PROPER OPERATION OF THIS SYSTEM.
SET RECEIVER'S DIP SWITCH
FOR DEVICE ADDRESS OF "0"
SEE RECEIVER'S INSTRUCTIONS
OPTIONAL
No. 4281L or 4281M
RF RECEIVER
OR
WIRELESS ZONES
4281L: UP TO 4
4281M: UP TO 8
BLK
RED
GRN
YEL
9
10
11
12
13
14
1000
1000
1000
1000
OHMS
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
AUX PWR
+
5
OUTPUT
BLK
-
TERMS
4
+
-
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
+
HEAT
*
ZONE 5
DETECTOR
-
*
IF PROGRAMMED FOR FIRE
15
16
17
18
19
20
TIP
RING
TIP
RING
(BROWN)
(GRAY)
(GREEN)
(RED)
HANDSET
INCOMING
PHONE LINE
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
1000
OHMS
AT TELCO JACK BEFORE
EOLR
SERVICING THIS UNIT.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PRO-
TECTION ASSOCIATION'S STANDARD 74 (NATION-
AL FIRE PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED INFORMA-
TION DESCRIBING PROPER INSTALLATION,
OPERATION, TESTING, MAINTENANCE, EVACUA-
TION PLANNING AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.
+
RED
–
•
•
EOL
POWER
SUPER-
VISION
VIOLET
RELAY
MODULE
•
A77-716B
1000
OHMS
•
EOLR
21
LOCATED AT
LOWER RIGHT OF
CIRCUIT BOARD
EARTH GROUND
SEE INSTRUCTIONS
FOR PROPER GROUNDING
DOC LOAD NO.: 3