Recommended installation
Valve
Non-return valve
Flood suction from tank above ground
INSTALLATION FOR LIFT SUCTION
- Check to ensure that a sufficient water level is available in the supply tank or bore
- Ensure that the ECOJET is securely fastened to stop any vibration that may cause slow wear of the pump
- Ensure that the pump is unplugged
- Ensure suction pipe has non-return valve (provided) fitted to the discharge of the water supply,
or fitted to the bottom end of the suction pipe
- Ensure the non-return valve is installed in the correct direction
- Ensure correct suction pipe sizes - see Tables 3.0, 3.1 and Chart 1.0
- Ensure that suction pipe is completely filled with water
- Ensure inlet and outlet pipes are correctly installed and tightened
- Remove top priming plug completely, fill pump body completely with water. This will take some time as it is a small
inlet and takes around 2L of water to fill the pump. Once full water will begin to spill over, fasten the priming plug with
a 14mm ring spanner
- Open main discharge valve
- Plug pump into main socket
- Run the highest and furthest valve/tap from the pump for 2 minutes (e.g. shower or garden tap on opposite side of
house)
- Close the discharge valve once excess air has evacuated the system
- Check for any leaks around the inlet/outlet pipes and the pump while the pump is still running
- Unplug the pump from main socket
- Check for any leaks around the inlet/outlet pipes and the pump when the pump is turned off
- If leaks are present, please tend to appropriately
- If no leaks are present, plug in pump to begin use of your ECOJET
Only once pump has been filled it has a self-priming capacity. Please ensure that pump has been sufficiently filled as
dry-running causes damage to the pump!
Leaks of any size, large or small will cause the pump to cycle and not function correctly and may void the warranty!
Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may differ slightly from those illustrated and described in this publication.
Valve
Drawing 4.0
Not recommended installation
Valve
Flood suction from tank above ground
Drawing 5.0
Tee w/plug
Non-return valve
Screen
Drawing 4.1
Non-return valve
9