All installations must comply with guidelines which are based on a zonal
concept. The diagram above illustrates this concept and must be followed to
ensure the safe installation of electrical appliances in the bathroom. These
regulations apply to domestic installations only. Installations must be made
in accordance with the current IEE wiring regulations and relevant building
regulations. HiB recommends that all electrical bathroom products should
only be fitted by a suitably qualified, Part P registered electrician.
Installation
1.
Position the mirror in a suitable location (according to the zonal
diagram, Fig. 1), ensuring that the domestic electrical mains supply is
within reach of the electrical entry point of the product.
2.
Carefully mark the position of the mirror using a soft pencil.
3.
Remove from wall and detach mirror from the frame by removing
screws on the exterior of the frame.
4.
Mark the drilling locations onto the wall according to the mounting
points diagram (Fig. A). Please ensure that all marked mounting
points accurately match up with the fixing points on the mirror.
5.
Before drilling, ensure there are no hidden cables or pipes behind
the mounting points. Using a masonry drill, drill holes in the marked
positions to a suitable depth. If drilling through tile, use a ceramic drill
bit.
6.
Insert wall plugs level with the surface of the wall. If fitting to a
tiled surface, wall plugs should be inserted below the tile surface to
avoid cracking. NB. For plasterboard walls, specialist fixings should be
purchased, available from any DIY or hardware store.
7.
Ensure the domestic electrical mains supply to which the mirror is
being connected is turned off. Feed the domestic mains supply wire
through the grommet on the mirror frame.
8.
Hold the frame in position, and screw through the holes in the frame
into the wall plugs.
9.
Connect the domestic mains supply to the terminal box according to
the wiring diagram (Fig. B).
10. Ensure the heated pad cable is connected and reattach the mirror to
the frame.
11. Switch the domestic electrical mains supply for the mirror back on.
Operation Instructions
To turn illumination on or off, wave hand under the sensor switch.
Heated pad is only on when mirror is illuminated.
LED Mirrors With Charging Socket Only:
NB. On first use of the charging socket, there may be resistance when
inserting the plug. Reasonable force may be required to fully insert the
plug. After a few uses, stiffness will ease and the socket will function as
normal.
T:
+44 (0)20 8441 0352
F:
+44 (0)20 8441 0219
Building 3, North London Business Park, Oakleigh Road South, New Southgate, London. N11 1GN
©HiB Copyright: No part of this document may be reprinted or duplicated without HiB consent. All sizes and measurements are approximate, but we do try and make sure they are as accurate as possible. In the interest
of continuous product development, HiB reserves the right to alter specifications as necessary. E & OE.
LED MIRRORS WITH CHARGING SOCKET
Ariel
Axis
Nexus
Vortex
LED BACK-LIT MIRRORS
Adelle
Alto
Larino
Livvy
Lucca
(Fig. 1)
Mileto
Vercelli
FLUORESCENT MIRRORS
Casey
Skye
Thank you for purchasing this HiB product.
Please read through these instructions carefully and refer back to them
during installation to ensure that your product is fitted safely and that it
retains its high quality finish.
Please retain this leaflet for future reference.
Before installation, ensure the domestic electrical mains supply to
which the mirror is to be connected is turned off. Before drilling,
ensure that there are no hidden cables or pipes in the wall.
Mounting Points Diagram (Fig. A)
NB. This product must be installed with a minimum distance of 150mm
between the infra-red sensor switch and any adjacent wall or object to
ensure correct operation of the sensor.
Care Instructions
Do not use abrasives or solvents when cleaning this product.
Wipe off all water spillages as soon as possible using a soft, damp cloth.
Aftercare Service
In the unlikely event that this product should fail please contact HiB
customer services, details shown below.
E:
hib.co.uk
Art No. 77470000
/ Astral
Art No. 77450000
Art No. 77417000
/ Epic
Art No. 77460000
/ Rotary
Art No. 77418000
Art No. 77419000
Art No. 77412000
/ Amber
Art No. 77420000
/ Christa
Art No. 77403000
/ Liberty
/ Louisa
Art No. 77405000
/ Messina
Art No. 77402000
/ Scarlet
Art No. 77409000
Art No. 77404000
/ Summer
Art No. 77309000
Art No. 77307000
REAR VIEW
mounting points
FI#01 001 R150909
Art No. 77416000
Art No. 77407000
Art No. 77413000
Art No. 77411000
Art No. 77406000
Art No. 77408000
Art No. 77410000
Art No. 77308000
Skye only
REAR VIEW
mounting points
alternate mouting points
Ver No.
1.0 Jan 2016