GAI-Tronics 1090 Manual de instalación y uso - Página 16

Navegue en línea o descargue pdf Manual de instalación y uso para Teléfono GAI-Tronics 1090. GAI-Tronics 1090 20 páginas. Hands-free telephones vandal resistant (vr) and help point

GAI-Tronics 1090 Manual de instalación y uso
Induction loop
(optional)
Dialling and
recall mode
Monitored faults
and sensors
Parameters
configurable with
TMA
Monitoring
method
Environmental limits
Temperature:
Relative Humidity
Ingress
Protection
Physical characteristics
Faceplate /
rear enclosure
material
Weight
Dimensions
16
Suitable for inductive coupling to Hearing Aids having
a `T' switch position. Supplementary power required.
MF only. TBR only.
Hookswitch
Brown out (power failure)
Call log full
4 auxilliary inputs (optional)
Autodial numbers - including time-switched alternate
numbers
Speech receive level.
Rings before / after auto-answer
Time out (default 7 minutes)
Mute before dial
DTMF detection window
Remote polling (initiated by TMA)
Call-in (initiated by the telephone at a preset time)
Operating: -20ºC to +60ºC
Storing: -40ºC to +70ºC
Up to 95% (non-condensing)
IP65 (from the front only unless fitted in the GAI-Tronics rear
enclosure) to EN60529:1992 – Degrees of protection provided
by enclosures.
Aluminium. Powder coated.
2kg without rear enclosure
4kg with rear enclosure
181W x 352H x 45D without rear enclosure
189W x 366H x 60D with rear enclosure
See section 5
VR & Help Point