GAI-Tronics 370-901 Manual - Página 9
Navegue en línea o descargue pdf Manual para Equipos de grabación GAI-Tronics 370-901. GAI-Tronics 370-901 19 páginas. Sp2 to page/party bridge
Model 370-901 SP2 to Page/Party
Mute Connection—P5
The muting conductor of the Page/Party
Terminal block P5 provides a dead ended termination for the muting conductor of the Page/Party
cable (see Figure 4):
1. Install a ferrule onto the end of the orange wire.
2. Connect the wire to pin one on pluggable terminal block P5.
3. Connect the pluggable terminal block to terminal block P5.
Power—P1
®
The SP2/Page/Party
Bridge operates from a 120/230 V
ac, 50/60 Hz power source. AC power is connected at
terminal block P1:
1. Pull the cable from the power source into the
enclosure.
2. Install ferrules onto the wire ends.
3. Connect the line, and neutral, conductors to the
pluggable terminal block (see Figure 4 and Table 6).
4. Connect the pluggable terminal block to terminal
block P1
Close the Enclosure
1. Reconnect the front cover to the rear enclosure by pushing the hinge pins on the front cover into the
holes on the left side of the rear enclosure until a click is heard.
2. Rotate the front cover to close the enclosure.
3. Install and tighten the four screws on the front cover.
Configuration
®
SP2 to Page/Party
Bridges are configured using the GUDA (GAI-TRONICS Universal Device
Application) software. Install the GUDA software and run it to configure Page/Party
1. Launch the GUDA application by double clicking the GAI-TRONICS Universal Device Application
shortcut from the start menu.
2. Choose the network interface to perform the discovery.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx
08/18
®
Bridge
®
system cable has no function in the SP2 to Page/Party
Table 6. AC Power—P1
Pin
Label
Description
P1-1
LINE
P1-2
NEUTRAL
P1-3
®
bridges as follows:
Pub. 42004-525A
Page 7 of 16
®
Bridge.
®
system
ac hot
no connection
neutral