GAIA Smart Thermostat Manual del usuario - Página 15
Navegue en línea o descargue pdf Manual del usuario para Termostato GAIA Smart Thermostat. GAIA Smart Thermostat 16 páginas.
1.
Sensor selection:
There are 5 options:
00 Floor sensor: uses the floor sensor only (default).
01 Room-in sensor: uses the built-in room sensor.
02 Room-in sensor and floor sensor: uses the built-in sensor with floor temperature limit.
03 Room-out sensor: uses a remote air sensor.
04 Room-out sensor and floor sensor: uses a remote air sensor with floor temperature limit.
2.
Room Temp Calibration: calibrate the temperature detected by room sensor.
Floor Temp Calibration: calibrate the temperature detected by floor sensor.
3.
4.
Floor Temp Limit: if you choose both sensors, floor temperature limit must be set to protect floor.
5.
Schedule: Select a weekly schedule for the event.
There are 2 options
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
6.
Used For: heating or cooling.
7.
Adaptive Function: after several days of installation and use, Adaptive Function ensures that the required
temperature has already been reached when the next event begins.
8.
Located In: Home or Office.
Reset: all parameters are restored to default values.
9.
Open Window Detection
This function only works when either the room sensor or both sensors are selected (refer to 6.2). When this
function is activated, the thermostat will shut off automatically for 15 minutes should it detect a sudden fall in
temperature, for example when a window is opened.
gaia
•
underfloor heating
15
•