Celestron 31032 Manual de instrucciones - Página 5

Navegue en línea o descargue pdf Manual de instrucciones para Telescopio Celestron 31032. Celestron 31032 16 páginas. 3"/4.5" newtonian telesccope
También para Celestron 31032: Manual del usuario (16 páginas)

3.
Slide the two top portions of each tripod leg around the sides of each flange on the tripod head
(#38) of the equatorial mount, so the flange is secured between them.
4.
Slide the screw through the tripod leg and flange, until the screw extends out the other side.
5.
Slide the washer and the nut over the screw and tighten. This can be left slightly loose, to allow
for positioning the legs later, when attaching the accessory tray.
6.
Repeat this process for the remaining two legs. Now the tripod will stand by itself.
You are now ready to attach the tripod accessory tray.
7.
The tripod tray fits over the holes in the tripod leg brace. Insert the winged bolts through the holes
in the bottom of the tripod leg brace and thread them into the holes in the accessory tray. Tighten
all bolts to ensure proper stability to the mount.
B. Before proceeding further, locate Right Ascension (#24) and Declination knobs (#22) and tighten them
finger tight.
1.
Locate the declination cable holder (#13). Locate the declination cable (the shorter of the two
cables) and attach the cable (#18) to the cable holder by tightening the thumb screw on the cable
end. The thumb screw should be tightened down hard on the flat surface of the cable holder after
backing off the cable about 1/4" from being fully engaged. This method helps ensure there is no
slippage when using the cable.
2.
You may reverse the position orientation of the Declination
cable to suit your preference if desired.
3.
Locate the right ascension cable holder (#27). Locate the right
ascension cable (#31) and attach it the same way as the
declination cable was attached in the last section.
Before mounting the optical tube, the counterweight must be
attached to the mount:
1.
Slide the counterweight shaft (#29) through the counterweight
(#30). Use the counterweight lock to lock the counterweight in
place. By holding the counterweight in one hand, thread the
counterweight shaft clockwise into the equatorial mount as
shown in figure 1.
C. Now you are going to put the telescope optical tube (#11) onto the equatorial mount.
For models #31041 and #31044:
1. Slightly loosen the screws that hold the mounting rings on the telescope in place.
2. Slide the rings apart so that each is at the same distance as the holes in the mounting platform.
3.
Place the telescope tube on the mount so that the flat portion of the tube rings rest on the mounting
platform.
4.
Align the holes on the square extrusions with the holes at the ends of the mounting platform.
5.
Starting with the ring closest to the focuser end of the tube, insert the bolt through the hole in the
mounting platform and thread it into the mounting ring. Repeat this process for the remaining
mounting ring.
5