HID Mercury MR52-S3B Instalaciones y especificaciones - Página 4
Navegue en línea o descargue pdf Instalaciones y especificaciones para Controladores de acceso IP HID Mercury MR52-S3B. HID Mercury MR52-S3B 19 páginas. Reader interface
Powering
Trusted Identities
1.1 MR52 reader interface
The MR52 reader interface boards provide a solution to the OEM system integrator for interfacing to TTL (D1/D0,
Clock/Data), F/2F, 2-wire RS-485 device and door hardware. The MR52 provides a tristate LED control, and buzzer
control.
Six Form-C relay outputs are provided that can be used for strike control or alarm signaling.
Eight inputs are provided that can be used for monitoring the door contact, request to exit push button, and alarm
contacts. Input circuits can be configured as unsupervised or supervised.
The MR52 communicates to the controller via a 2-wire RS-485.
1.1.1 Component location
Some components shown are not present on the MR52.
PLT-06451, A.1
HID® Mercury™ MR52-S3B Reader Interface
4
Installation and Specifications
September 2023