DynaLock 3000LC Series Manual de instrucciones de instalación - Página 4
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Por cerraduras DynaLock 3000LC Series. DynaLock 3000LC Series 12 páginas. Electromagnetic lock
También para DynaLock 3000LC Series: Instrucciones de instalación (4 páginas), Manual (6 páginas)
DynaLock
705 Emmett Street
Ph/ 860.582.4761
1.
Use the figure below to identify and mark the locations of the armature mounting bracket screw holes on each door
leaf. Refer to door and frame prep drawing #301095 for further information.
1-3/8"
FROM
FRAME
RABBET
From the illustrations below select the one that resembles your door type and follow the instructions for drilling the
2.
two (2) armature mounting bracket screw holes on each door leaf.
GLASS & ALUMINUM
OR HOLLOW METAL DOOR
DOOR
SPACER
SEX
NUT
21/32"
Drill an 11/32" diameter hole
through door. From sex nut side
only enlarge the 11/32" hole to
21/32" diameter.
Mount the armature and mounting bracket assemblies to each door leaf using the appropriate hardware for you
3.
door type. Frimly tighten the mounting screws with a 3/16" hex wrench.
3001xTJ31 MANUAL - FORM 3001TJ-001
Bristol, CT 06010
?
Fx/ 860.585.0338
?
INSTALL THE ARMATURE MOUNTING BRACKETS
2-1/4"
3/4" FROM
CENTER OF
OPENING
LOWER
ARMATURE
MOUNTING
BRACKET
1"
ARMATURE BRACKET
MOUNTING SCREW
1/2"
Drill an 11/32" diameter hole
through door. From sex nut side
only drill 1/2" diameter hole to
1" depth.
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
L
CENTERLINE
2-1/4"
3/4" FROM
CENTER OF
OPENING
L
SOLID CORE DOOR
LOWER
ARMATURE
MOUNTING
BRACKET
ARMATURE BRACKET
MOUNTING SCREW
Page 4
SERIES 3001xTJ31
REINFORCED DOOR
5/16"-18 THREAD
Drill an 11/64" diameter hole and
tap for 5/16"-18 thread.
LOWER
ARMATURE
MOUNTING
BRACKET
ARMATURE BRACKET
MOUNTING SCREW
11/02