Gainsborough G+ LOCKSET Manual de instrucciones de instalación - Página 6
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Por cerraduras Gainsborough G+ LOCKSET. Gainsborough G+ LOCKSET 8 páginas. G+ series for the apex electric locksets and volt electric locksets
Task 3
13
14
15
Turn key clockwise
Inside
door face
Rotor
Make sure the
connectors are
pushed together
Turn key clockwise
NOTE: The mounting plate must first be removed from the
inside faceplate.
• Insert key and turn clockwise.
• Remove the mounting plate.
• The key can now be turned back to the vertical position
and removed.
• The rotor is pre-installed onto the mounting plate. The rotor
must be positioned such that one notch faces upwards, and
the other notch faces towards to latch side (door opening).
• Mount and hold the outside faceplate onto the outside
door face. Assemble the mounting plate to the outside face
plate. Make sure the connector wires pass through the large
rectangular hole in the mounting plate and that the spindle
engages the outside lever.
• Fit 2 mounting screws from KIT B and tighten.
NOTE: If "KIT B" contains 2 length of screws then use the
following guide:
• For doors up to 40mm thick use the 2 "short" screws.
• For doors 40mm and over use the 2 "long" screws.
• Insert key into the inside faceplate and turn clockwise.
Leave key in this position.
• Assemble the connector from the Battery Box with the
connector on the faceplate. Make sure they are firmly
pressed together.
NOTE: Do not let go of the faceplate or allow the faceplate
to "hang" from the wires.
• Hold the faceplate flush against the door face making sure
that wires from the Battery Box are not trapped. The key can
now be turned back to the vertical position and removed.
The faceplate is now temporarily secured and will not fall
if let go.
• Fit 4 mounting screws from KIT C and tighten.