STEP 5: STARTING THE AMPLIFIER
a) Reconnect the COAX cable RF output on the 001-000181-01 board.
b) Switch on the amplifier and check if the "Set Pout" is set to maximum on the "[02]
Power Fwd" menu on the display. If not, set the output power to maximum.
c) Press RF ON/OFF button on the front panel to enable the RF.
d) On the 001-000166-02 board adjust the RT7 trimmer to set the maximum power of the
amplifier.
Fig. 18 – Control board RT7 adjust
Mozart series calibrating procedure