14. USER COMMANDS

You can program many different user command codes in a single text message with SMS command
format. *12*1234 # [command Code1] # [command Code 2] # [command Code3] #........
No.
Command
1
01 [new password]#
2
02[new password]#
3
11[Time]#
4
12[Time]#
5
13[Time]#
6
14[Time]#
7
15[Time]#
8
16[Time]#
9
17[Time]#
10
23[Time]#
11
24[Time]#
18[Status]#
12
19[Status]#
13
22[Status]#
14
20[mode]#
15
3G Gate Opener
Description
Change password of
Programming Mode
Change password of Access
control Mode
Door open confirming time
Relay 1 activation time
Relay 2 activation time
Activation time when input 1 is
trigged
Sending SMS duration when
input 1 continues triggering
Activation time when input 2 is
trigged
Sending SMS duration when
input 2 continues triggering
Activation time when input 3 is
trigged
Sending SMS duration when
input3 continues triggering
Set Input1 status
Set Input 2 status
Set Input 3 status
Set Input 1 mode
14/17
settings
password:4 ~6digits
password:4 ~6digits
Time = 0~99 seconds
Time = 1~9999 seconds
Time = 1~9999 seconds
Time = 1~9999 seconds
Time = 0-60 minutes
Time = 1~9999 seconds
Time = 0-60 minutes
Time = 1~9999 seconds
Time = 0-60 minutes
Status= 0 or 1
0=N.O
1=N.C
Status= 0 or 1
0=N.O
1=N.C
Status= 0 or 1
0=N.O
1=N.C
Mode= 0, 1 , 2 or 3
0 = Disable , 1 = Trigger
2 = Egress 1, 3= Egress2
Revision V1.3B, Jan 2020
Default
1234
5678
0 sec
no delay
1
1
0 sec
no delay
15[Time]
#
0 sec
no delay
0 min
no delay
0 sec
no delay
0 min
no delay
0
0
0
1