9.
Ozone Sterilization
Press this button for 2 seconds , the ozone function starts and works for 10 minutes and then stops;Or press
twice to stop the function.
10.
Thermostatic Heating
10.1 This Function works only when the water pump surf function is on.
10.2 Press button to start the function, and press"
range:35℃--45℃).
10.3 Thermostatic heating function starts or stops according to the temperature ( the temperature that the system
o
C) :
defaults is 37
Panel 2
1
When any function button works, there is a sound of di... di... .
2
Adjusting button
Adjusting button can turn both right and left. It takes cell as unit, turn on cell, one operation was made. Turn right
or turn left can operate the functions.
3
Note of Icons and cursor
- Icons like
are directing icons, all the directing icons are displaying on LCD after power on.
-
is cursor which shows only one on LCD. Turn right,
downward.
stands for the function is selected, press
-
are function icons, function icon will not display if the function was not selected by cursor; the
function icon will display on LCD if cursor selected it and will blinks if the function was start. Take FM function
as example, if cursor select
4
Power
Press the icon to start the controller, press again to stop the controller.
Controlling rule is as follows:
If the temperature≥ setting temperature+1℃,stop heating;
If the temperature≤ setting temperature -1℃,start heating.
, will display on the right side of
" or "
"to adjust the temperature.(Temperature setting
moves upward, turn left,
to start the function.
, that is
moves
.