DEVICE SPECIFICATIONS

MODEL: F170A
Operation Voltage: 120 VAV, 60 Hz
Power Button Function: ON / 1 / 2 / 3 / 4 / OFF
Operational Indicators:
Green ring – power on, device in operation
Filter change – activates after 180 days of usage
Photocatalyst cell (ActivePure®) – activates after 365 days of usage
Reset Button:
Press and hold power button for 10 seconds to reset filter and/or cell
indicators
Ionizer Voltage: 4.5 ~ 5.5 kV
Negative Ion Output (Avg): 8.73 x 10
Treatment Area: 3,000 ft
with ceilings 8 ~ 10 ft
3
Recommended Fan Speed: High
Fan Speeds / Fan Indicators: 4
Whisper
|
1 blue bar is illuminated
Low
|
2 blue bars are illuminated
Medium |
3 blue bars are illuminated
High
|
4 blue bars are illuminated
Nominal Airflow Rate:
Whisper
|
90 CFM
|
53 m
/h
3
Low
|
100 CFM
|
59 m
/h
3
Medium |
180 CFM
|
305 m
High
|
300 CFM
|
509 m

OPERATION

WARNING:
DO NOT place the unit:
• Directly on or near soft furnishing (such as bedding or curtains)
• Near sources of heat (such ad radiators, fireplaces or ovens)
• Near combustible gasses
• Near water, outdoors or in a damp or wet area
Place the ActivePure® Medical Guardian in a location that allows air to move freely into, around and out of the unit. Allow minimum of 12" of
clearance around intake grill (airflow input).
6
/ cm
6
3
/h
3
/h
3
Nominal Wattage:
Standby
1
Whisper
41
Low
46
Medium
60
High
117
Average Sound (dbA)(i):
Whisper
43
Low
48
Medium
64
High
70
(measured @1m from front)
Dimensions:
26.5"H x 11.5"W x 21.0"D
673mm H x 292mm W x 533mm D
Weight:
48 lbs.
21.8 kg
Power Cord: 6 ft.
ActivePure® Medical, LLC reserves the right to change or modify any
specifications without notice. Consult www.ActivePureMedical.com for the
latest device information or consult Customer Service at 1.800.572.0317.
Life:
3-years minimum operational life