The following is a summary of the Expert Mode in the form of a flow chart. Step-by-step instructions for
the Expert Mode follow this chart.
SET TO CONFIRM ?
0 = NO 1 = YES
Zn ZT P RC In
10 03 1 10
[ ]
In =
HW
10
INPUT S/N
A XXX-XXXX
[ ]
No
Is Confirm
bit set?
Yes
Confirm by transmission
Summary of Expert Mode ( 93)
0
L
-
RF
In =
RF, BR,
UR or SL
L
1
•
Question is asked once upon entering mode
•
Default is "No"
•
If "Yes," Confirmation prompts are displayed after the device's
serial number and loop number have been entered later
•
Enter zone number and press [ ]
•
Enter all information in this screen except for Loop Number
•
Use A (forward) and B (back) keys to move cursor within the
screen
•
Press "C" key (with cursor under "ZT") to copy the last
enrolled zone's attributes
•
Press "D" key (with cursor under "Zn") to enter and duplicate
wireless keys — skip to chart on next page
•
Press (#) to back up without saving
•
Press[ ] to accept existing information
•
Enter serial number, either manually, or by two open and close
(or close and open) sequences. On button type transmitters,
press the button twice, but wait approximately 4 seconds before
pressing the button the second time.
To copy previous zone's serial number, press "C" key
•
Use A and B keys to move cursor within screen
•
Press [ ] to accept serial number, then enter loop number
•
Press [ ] to accept existing serial and loop number
•
System checks for duplicate
•
If duplicate exists (long error beep), press (#) to back up
without saving and re-enter serial and/or loop number
•
Prompt to confirm appears if YES was answered to first prompt
•
To confirm, activate loop input or button that corresponds to
this zone
•
If serial number entered matches serial number transmitted, the
system will advance to the summary display for the next zone's
programming.