5. Auto-draining System
New strong automatic draining system, it can auto-back flush to wipe out scale completely,
reduce the mineral accumulation and extension the service life extremely.
Rinse
valve
Water inlet

5-1. Installation

A) Set up the Two-ways valve and Actuator together, then install it to the water outlet -rinse
valve.
B) Connect the Actuator cable with that on steamer.
5-2. Operation
A) Set the control mold at "AUTO" position, when the machine stop working for 15mins, the
mainboard sends signal to open the drainer, and after 3mins, water inlet valve opens, and let
the water flush 1min to wipe out scale. Then the water inlet valve and drainer valve close.
B) If set the control mold to "MAN" , then need to drain the water by manual.
Control Mode
Auto-draining
current
AUTOMATIC
MANUAL
Actuat
Two-