Autonics TM Series Manual - Página 3

Navegue en línea o descargue pdf Manual para Controlador de temperatura Autonics TM Series. Autonics TM Series 9 páginas. Modular 4-channe pid temperature controllers with screwless connector
También para Autonics TM Series: Manual del producto (4 páginas)

Autonics TM Series Manual
TM Series
Dimensions

Unit Description

9
8
5
1
5. Indicators
●TM2 Series
●●●●●●●●●●●●●●●●●●Status
Initial●power●ON
Indicator
※3
PWR●(green)
ON●
CH1●(red)
Flash●(2,400bps)
CH2●(red)
Flash●(4,800bps)●
AL1●(yellow)
Flash●(9,600bps)
AL2●(yellow)
Flash●(19,200bps)
AL3●
Flash●(38,400bps)
AL4●
-
※1:●When●power●is●supplied●initially,●the●set●communication●speed●LED●flashes●for●5●sec.●
●TM4 Series
●●●●●●●●●●●●●●●●●●Status
Initial●power●ON
Indicator
※3
PWR●(green)
ON●
CH1●(red)
Flash●(2,400bps)
CH2●(red)
Flash●(4,800bps)●
CH3●(yellow)
Flash●(9,600bps)
CH4●(yellow)
Flash●(19,200bps)
Flash●(38,400bps)
6. Communication address setting switch (SW1): Set●the●communication●address.●●
7. Communication address group switch (SW2): When●setting●the●communication●address●over●16,●select●+16.●
8. Lock switch: Used●for●fixing●modules●at●top●and●bottom.
9. Rail Lock: Used●for●installing●at●DIN●rail●or●using●bolts.●
10. END cover:●Remove●it●when●connecting●each●module●to●connect●an●expansion●connector.●
H-12
84.8
18.6
103.4
7
1. Sensor input connector
2. Control output connector
4
3. Power/Comm. terminal●
6
10
2
4. PC loader port
3
Alarm●output
Control●
※1
N.O.●(Normally●Open)
output
OFF●(OPEN)
ON
-
ON
-
ON
-
※4
ON
OFF
※5
ON
OFF
-
OFF
-
OFF
Control●
Auto-
※1
output
tuning
ON
ON
ON
Flash
ON
Flash
ON
Flash
ON
Flash
-
-
2.9
30
[only●for●basic●module●(TM - 2 B)]
Suppling●power●to●basic/expansion●modules●and●communicating●with●
over●1●module●(s).
It●is●the●PC●loader●port●for●serial●communication●between●one●module●
and●PC●to●set●parameter●and●monitoring●by●DAQMaster.●Use●this●for●
connecting●SCM-US●(USB●to●serial●converter,●sold●separately).●●●
※● W hen●using●PC●loader●port●(connecting●SCM-US),●communication●via●
power/comm.●terminal●is●blocked●and●monitoring●is●not●available.●
N.C.●(Normally●Closed)
ON●(CLOSE)
OFF●(CLOSE) ON●(OPEN)
-
-
-
-
-
-
ON
OFF
ON
OFF
ON
OFF
ON
OFF
※2:●The●auto-tuning●CH●LED●flashes●for●1●sec●in●turn.
※3:●The●PWR●LED●flashes●during●communication●for●1●sec●in●turn.
※2
※4:●Turns●ON●when●CH1●control●method●is●heating●&●cooling●control●
and●cooling●output●occurs.●●
(disable●AL1●setting)
※5:●Turns●ON●when●CH2●control●method●is●heating●&●cooling●control●
and●cooling●output●occurs.●●
(disable●AL2●setting)
Auto-
※2
tuning
-
ON
-
Flash
-
Flash
ON
OFF
ON
OFF
ON
OFF
ON
OFF
●(unit:●mm)