dbx iEQ-15 Manual del usuario - Página 13
Navegue en línea o descargue pdf Manual del usuario para Equipos de grabación dbx iEQ-15. dbx iEQ-15 16 páginas. Graphic eq
También para dbx iEQ-15: Especificaciones (2 páginas), Manual del usuario (20 páginas), Resumen rápido (4 páginas)
iEQ
The iEQ Series Equalizers have balanced inputs and outputs that can be used with any balanced
or unbalanced line-level device.
To connect the equalizer to your sound system refer to the following steps:
• Turn off all equipment before making connections.
• Mount equalizer in a standard-width rack.
Install the EQs in a rack with the rack screws provided. It can be mounted above or below
anything that does not generate excessive heat. Ambient temperatures should not exceed
113° F (45°C) when equipment is in use. Although the unit's chassis is shielded against radio
frequency and electromagnetic interference, extremely high fields of RF and EMI should be
avoided.
• Make audio connections via XLR, 1/4" TRS jacks or Euroblock connectors according to applica-
tion needs. All three types of connectors for the inputs and outputs can be used for balanced
or unbalanced connections. The use of more than one connector at a time for the inputs could
unbalance balanced lines, cause phase cancellation, short a conductor to ground, or cause dam-
age to other equipment connected to the equalizer. More than one output may be used simul-
taneously as long as the combined parallel load is greater than 600Ω.
• Select the operating range with the boost/Cut range selection switch
Note: Be sure to reduce audio levels at the power amplifiers when changing the setting of this
switch as it may generate an audible transient.
• Apply power to the equalizer. Connect the AC power cord to the AC power receptacle on the
back of the equalizer. Route the AC power cord to a convenient power outlet away from audio
lines. The unit may be turned on and off from the rear panel power switch or a master equip-
ment power switch. Since the iEQ Series Equalizers consume a relatively small amount of power,
the units may be left on continuously.
®
Basic Connection
Basic Connection of the iEQ
Operation
iEQ User Manual
6