Connections
● FX Y-I4
※ (INHIBIT) PNP NPN
1
2
3
CP1
CP2 12VDC
50mA
※ INHIBIT: In case of timer mode, this terminal is for time hold.
(voltage input (PNP): connect with 12VDC, no-voltage input (NPN): connect with 0VDC)
Dimensions
72
Bracket
60

Counting Method

Be careful to select sensor because the counting method of NPN output type sensor is different from PNP
output type sensor.
NPN output type proximity sensor
: When the sensor is changed from OFF to ON, it counts.
Target
PR18-5DN
Have
Target
None
ON
LED
OFF
Counting number
M-68
4
5
6
7
0VDC RESET
SOURCE:
100-240VAC
50/60Hz 3.8VA
6
2
1
0
● FX Y-I2
※ (INHIBIT)
PNP
NPN
1
2
3
4
CP1
CP2 12VDC
0VDC RESET
50mA
SOURCE
: ● 24VAC 50/60Hz 2.8VA
● 24-48VDC 1.8W
77
Panel cut-out
Min. 91
PNP output type proximity sensor
: When the sensor is changed from ON to OFF, it counts.
Target
PR18-5DP
Have
Target
None
ON
LED
OFF
Counting number
5
6
7
(unit: mm)
+0.7
68
0
2
1
0