Autonics M4V Series Manual del producto - Página 3

Navegue en línea o descargue pdf Manual del producto para Instrumentos de medida Autonics M4V Series. Autonics M4V Series 3 páginas. Mosaic panel meters for mosaic panels (indicator)

Autonics M4V Series Manual del producto
Mode Setting
RUN
[▲] + [◀] 3 sec
Parameter Setting
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
Changes setting digits.
• [◀] key:
Changes setting values. /
[▲] key:
Save current parameter setting value and move to
next parameter (When pressed for 2 sec)
■ Parameter group
Parameter
Display Defaults
Measurement
1-1
input type
IN-T
0-2V
Low-limit
1-2
0000 -999 to 9999
scale
L-SC
High-limit
1-3
)0 -999 to 9999
scale
H-SC
Decimal
1-4
point
)0 0.0, 0.00, 0.000, 0
DOT
position
Low-limit
1-5
display value
0000 -99 to 99
IN-B
correction
1-6
Lock
OFF ON, OFF
LOC
Error
Error display is released automatically when it is in the measured and display range.
Display
Description
Flashes when measurement input is higher than
the input range
E.g.) Measurement input type = DC 4-20 mA, error
HHHH
display flashes when DC 22 mA or more is
input.
Flashes when measurement input is lower than
the input range
E.g.) Measurement input type = DC 4-20 mA, error
LLLL
display flashes when DC 2 mA or less is input.
Flashes when the wiring is wrong or when a error
occurs in the measurement input
OVER
Flashes when a memory chip that stores the
setting values of the device is damaged, external
noise, or malfunction of the power supply stage,
ER-E
etc.
[▲] 2 sec + [▲] 2 sec
• Return to run
mode after saving
parameter setting
Parameter
value
group
[▲] 2 sec
• Return to run mode
without changing
parameter setting
value
Setting range
0-2V, 1-5V, 0-10V,
1MA: DC 0 - 1 mA , 4-20: DC 4 - 20 mA
Troubleshooting
Disconnect power supply
and check the cables.
Disconnect power
supply and check the
measurement input.
Consult your Autonics sales
representative.
Connections of Applications
■ Simulaneous connection of voltmeter and ammeter
+
Load
power
-
HI
RUN
Voltmeter
DC power
supply 1
• A: Compared to measurement input range, higher measuring voltage needs a multiplier and
lower measuring voltage needs a shunts.
• Connect the separated power supply each.
• (-) terminal of the power and (-) terminal of measurement input are shorted.
In case of using same power supply, measurement error or overcurrent may occur.
■ Scaling meter connection
Temperature
Sensor
Pressure
Sensor
High / Low-limit scale value
This function is to display setting of particular high / low-limit value in order to display high /
low-limit value of measured input.
If measured inputs are a and b and particular values are A and B, it will display a = A, b = B as
below graphs.
• Set the high / low-limit scale values to be at least 1 or more different.
Display
value
B
A
a
b
Input
value
Display
value
A
B
a
b
Input
value
Segment Table
The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 segment
0
0
I
1
1
J
2
2
K
3
3
L
4
4
M
5
5
N
6
6
O
7
7
P
8
8
Q
9
9
R
A
A
S
B
B
T
C
C
U
D
D
V
E
E
W
F
F
X
G
G
Y
H
H
Z
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-2-2048-1577 | [email protected]
+
-
A
Load
LOW
HI
LOW
Ammeter
DC power
supply 2
+
Hi
OUTPUT:
0 - 2 VDCᜡ
1 - 5 VDCᜡ
Panel
CONVERTER
0 - 10 VDCᜡ
meter
DC 0 - 1 mA
DC 4 - 20 mA
Low
-
Display
Display
value
value
B
B
A
A
a
b
Input
value
Display
Display
value
value
a
b
A
Input
A
value
B
B
11 segment
12 segment
I
0
I
0
0
I
0
I
J
1
J
1
1
J
1
J
K
2
K
2
2
K
2
K
L
3
L
3
3
L
3
L
M
4
M
4
4
M
4
M
N
5
N
5
5
N
5
N
O
6
O
6
6
O
6
O
P
7
P
7
7
P
7
P
Q
8
Q
8
8
Q
8
Q
R
9
R
9
9
R
9
R
S
A
S
A
A
S
A
S
T
B
T
B
B
T
B
T
U
C
U
C
C
U
C
U
V
D
V
D
D
V
D
V
W
E
W
E
E
W
E
W
X
F
X
F
F
X
F
X
Y
G
Y
G
G
Y
G
Y
Z
H
Z
H
H
Z
H
Z
Power
supply
Input
a
b
value
a
b
Input
value
16 segment
I
0
I
0
I
J
1
J
1
J
K
2
K
2
K
L
3
L
3
L
M
4
M
4
M
N
5
N
5
N
O
6
O
6
O
P
7
P
7
P
Q
8
Q
8
Q
R
9
R
9
R
S
A
S
A
S
T
B
T
B
T
U
C
U
C
U
V
D
V
D
V
W
E
W
E
W
X
F
X
F
X
Y
G
Y
G
Y
Z
H
Z
H
Z