■ Parameter 2 group
Parameter
Mark
Defaults Setting range
Output
2-1
operation
OUtT
OFF
mode
2-2
Hysteresis
HYS
001
Startup
2-3
compensation
STaT
0)0
time
Peak
2-4
monitoring
00 S 00 to 30 sec
PEkT
delay time
2-5
Display cycle
)2 S 0.1 to 5.0 sec
DIsT
Keys for zero
2-6
adjustment
ZERO
NO
External
2-7
input
EVLN
HOLD
terminal
50)0
High-limit
value of
2-8
transmission
FS-H
output
%000
00)0
Low-limit
value of
2-9
transmission
FS-L
output
)000
Comm.
2-10
Address
ADRS
01
Comm.
2-11
speed
BPS
9600
2-12 Parity bit
PRTY
NONE
2-13 Stop bit
STP
Response
2-14
waiting time
RSwT
2-15 Lock
LOC
OFF
■ Parameter 0 group
Parameter
Mark
Defaults Setting range
50)0
Output high-
0-1
limit output
hSET
setting value
%000
00)0
Output low-
0-2
limit output
lSET
setting value
)000
Display max.
)0
0-3
peak value
01)
hPEK
)000
Display min.
)0
0-4
peak value
01)
lPEK
)000
01)  Reset: Press any one of [◀], [▼], [▲] keys.
[Except indicator model]
OFF, L.ST, H.ST, LH.ST, HH.ST, LL.ST,
LD.ST
• Refer to Output Operation Mode
[Except indicator model]
Within 10 % of max. display range, digit
[Except indicator model]
0.0 to 99.9 sec
NO, YES
• YES: Press the [◀] + [▲] keys for 3
sec to adjust zero.
[Except indicator model]
HOLD, ZERO
• If the external input terminal is
short-circuited for 50 ms or more, it
operates with the set function.
[DC voltage & Transmission (DC 4 - 20
mA) output model],
[AC voltage & Transmission (DC 4 - 20
mA) output model]
Max. value of display range
[DC current & Transmission (DC 4 - 20
mA) output model],
[AC current & Transmission (DC 4 - 20
mA) output model]
Max. value of display range
[DC voltage & Transmission (DC 4 - 20
mA) output model],
[AC voltage & Transmission (DC 4 - 20
mA) output model]
Min. value of display range
[DC current & Transmission (DC 4 - 20
mA) output model],
[AC current & Transmission (DC 4 - 20
mA) output model]
Min. value of display range
[RS485 Comm. output model]
01 to 99
[RS485 Comm. output model]
38.4k, 19.2k, 9600, 4800, 2400, 1200 bps
[RS485 Comm. output model]
NONE, EVEN, ODD
[RS485 Comm. output model]
2, 1 bit
2
[RS485 Comm. output model]
5 to 99 sec
5
OFF: unlock,
LOC1: lock parameter 1,
LOC2: lock parameter 1, 2,
LOC3: lock parameter 0, 1 and 2
[DC voltage & Preset setting model]
-5 to 110 % of display range
[AC voltage & Preset setting model]
0 to 110 % of display range
[DC current & Preset setting model]
-5 to 110 % of display range
[AC current & Preset setting model]
0 to 110 % of display range
[DC voltage & Preset setting model]
-5 to 110 % of display range
[AC voltage & Preset setting model]
0 to 110 % of display range
[DC current & Preset setting model]
-5 to 110 % of display range
[AC current & Preset setting model]
0 to 110 % of display range
[DC voltage], [AC voltage]
Max. peak value in run mode
[DC current], [AC current]
Max. peak value in run mode
[DC voltage], [AC voltage]
Min. peak value in run mode
[DC current], [AC current]
Min. peak value in run mode
Input Range and Display Range
Display
When the max. input value is over the 100 %, it may result in input terminal damage.
condition
■ DC voltage model
Display range
-
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
0 - 500 VDCᜡ
0.0 to 500.0
2-1
0 - 100 VDCᜡ
0.0 to 100.0
Output
operation
0 - 50 VDCᜡ
0.00 to 50.00
mode:
0 - 10 VDCᜡ
0.00 to 10.00
except
0 - 5 VDCᜡ
0.000 to 5.000
OFF
0 - 1 VDCᜡ
0.000 to 1.000
-
0 - 250 mVDCᜡ
0.0 to 250.0
0 - 50 mVDCᜡ
0.00 to 50.00
01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
-
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
-
■ DC current model
Display range
-
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
0 - 5 A
0.000 to 5.000
0 - 2 A
0.000 to 2.000
-
0 - 500 mA
0.0 to 500.0
0 - 200 mA
0.0 to 200.0
0 - 50 mA
0.00 to 50.00
4 - 20 mA
4.00 to 20.00
0 - 5 mA
0.000 to 5.000
0 - 2 mA
0.000 to 2.000
-
01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
■ AC voltage model
Display range
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
0 - 500 VACᜠ
0.0 to 500.0
0 - 250 VACᜠ
0.0 to 250.0
-
0 - 110 VACᜠ
0.0 to 440.0
02)
0 - 50 VACᜠ
0.00 to 50.00
0 - 20 VACᜠ
0.00 to 20.00
0 - 10 VACᜠ
0.00 to 10.00
0 - 2 VACᜠ
0.000 to 2.000
-
0 - 1 VACᜠ
0.000 to 1.000
01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
-
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
02)  In case of 0 to 110 VACᜠ of AC voltage range and using P.T (potential transformer) for 440 VACᜠ / 110 VACᜠ, if
-
110 VACᜠ is input, and the unit displays 440 VACᜠ automatically by preset scale value for P.T user's convenient.
■ AC current model
-
Display range
Input range
-
Diaplay method: STND (fixed) Diaplay method: SCAL
0 - 5 A
0.000 to 5.000
0 - 2.5 A
0.000 to 2.500
-
0 - 1 A
0.000 to 1.000
0 - 500 mA
0.0 to 500.0
0 - 250 mA
0.0 to 250.0
0 - 100 mA
0.0 to 100.0
Display
0 - 50 mA
0.00 to 50.00
condition
01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
2-1
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
Output
operation
mode:
except
OFF
2-1
Output
operation
mode:
except
OFF
2-1
Output
operation
mode:
except
OFF
&
2-4 Peak
monitoring
delay time:
except 00
01)
500V
Decimals
Display range
100V
0 -1999 to 9999
50V
)0 -199.9 to 999.9
10V
)00 -19.99 to 99.99
5V
)000 -1.999 to 9.999
1V
)25V
50MV
01)
5A
Decimals
Display range
2A
0 -1999 to 9999
)5A
)0 -199.9 to 999.9
)2A
)00 -19.99 to 99.99
50MA
)000 -1.999 to 9.999
4-20
5MA
2MA
01)
500V
Decimals
Display range
250V
0 -1999 to 9999
110P
)0 -199.9 to 999.9
50V
)00 -19.99 to 99.99
20V
)000 -1.999 to 9.999
10V
2V
1V
01)
5A
Decimals
Display range
@5A
0 -1999 to 9999
1A
)0 -199.9 to 999.9
)5A
)00 -19.99 to 99.99
)25A
)000 -1.999 to 9.999
)1A
50MA
Input
impedance
4.33348 MΩ
4.33348 MΩ
433.48 kΩ
433.48 kΩ
43.48 kΩ
43.48 kΩ
2.28 kΩ
2.28 kΩ
Input
impedance
0.022 Ω
0.022 Ω
0.222 Ω
0.222 Ω
2.222 Ω
2.222 Ω
22.222 Ω
22.222 Ω
Input
impedance
5.01092 MΩ
5.01092 MΩ
1.11092 MΩ
1.11092 MΩ
200.92 kΩ
200.92 kΩ
20.92 kΩ
20.92 kΩ
Input
impedance
0.02 Ω
0.02 Ω
0.102 Ω
0.202 Ω
0.202 Ω
1.022 Ω
1.022 Ω