Autonics AT11DN Series Manual de instrucciones

Navegue en línea o descargue pdf Manual de instrucciones para Timer Autonics AT11DN Series. Autonics AT11DN Series 1 páginas. Multi function timer

Autonics AT11DN Series Manual de instrucciones
DRW171149AA
MULTI FUNCTION TIMER
AT11DN/AT11EN SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.

Safety Considerations

※Please observe all safety considerations for safe and proper product operation to avoid hazards.
※Safety considerations are categorized as follows.
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage.
※The symbols used on the product and instruction manual represent the following
symbol represents caution due to special circumstances in which hazards may occur.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury
or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles,
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in fire, personal injury, or economic loss.
2. Install on a device panel to use.
Failure to follow this instruction may result in electric shock or fire.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or fire.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in fire.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or fire.
Caution
1. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or fire.
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight,
radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in fire or explosion.
4. Keep metal chip, dust, and wire residue from flowing into the unit.
Failure to follow this instruction may result in fire or product damage.

Ordering Information

AT 11 DN -
100-240VAC 50/60Hz,
No mark
Power
24-240VDC
supply
1
12VDC
2
24VAC 50/60Hz, 24VDC
Time operation
DN
Time limit 2c
Instantaneous 1c
EN
+ Time limit 1c
Number of plug pins
11
11-pin plug type
Item
AT
Analog Timer
※Sockets (PG-11, PS-11(N)) are sold separately.
Unit Description
Time limit output
Operation/Power indicator
indicator
(Flashes for timer operation,
Turns ON for timer stop)
Output operation
mode indicator
Time range indication
(A, F, F1,
Time range setting switch
C, D, I
mode)
Output operation mode indicator
Output operation
(sec, min, hour, 10h mode)
mode setting SW
Connections
AT11DN SERIES
AT11EN SERIES
RESET
RESET
START
CONTACT OUT:
START
250VAC 5A
6
INHIBIT
5
7
INHIBIT
RESISTIVE LOAD
4
8
(Instantaneous
(Time limit
1c)
3
9
1c)
10
2
1
11
(Time limit 1c)
※1
※1: AC/DC voltage: 100-240VAC 50/60Hz, 24-240VDC
: 24VAC 50/60Hz, 24VDC
DC voltage: 12VDC
※The above specifications are subject to change and some models may be discontinued
without notice.
※Be sure to follow cautions written in the instruction manual and the technical descriptions
(catalog, homepage).
Dimensions
48
Bracket
48.6
45
55
56
Output Operation Mode
Mode
Time chart
A
Signal ON
Time limit contact N.C.
Delay
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator
Time Specifications
F
Time range Time unit Time setting range
0.5
0.05 to 0.5 sec.
Flicker
Time limit contact N.C.
1.0
0.1 to 1 sec.
(OFF Start)
sec
Time limit contact N.O.
5
0.5 to 5 sec.
Time limit output indicator
Operation/Power indicator
10
1 to 10 sec.
0.5
0.05 to 0.5 min.
F1
1.0
0.1 to 1 min.
min
5
0.5 to 5 min.
10
1 to 10 min.
Flicker 1
0.5
0.05 to 0.5 hour
Time limit contact N.C.
(ON Start)
Time limit contact N.O.
1.0
0.1 to 1 hour
hour
Time limit output indicator
5
0.5 to 5 hour
Operation/Power indicator
10
1 to 10 hour
C
0.5
0.5 to 5 hour
1.0
1 to 10 hour
10h
5
5 to 50 hour
Signal OFF
10
10 to 100 hour
Time limit contact N.C.
Delay
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator
D
CONTACT OUT:
Signal
Time limit contact N.C.
250VAC 5A
ON/OFF
6
5
7
Time limit contact N.O.
RESISTIVE LOAD
Delay
Time limit output indicator
4
8
Operation/Power indicator
3
9
I
2
10
1
11
(Time limit 1c)
Interval
※1
Time limit contact N.C.
Time limit contact N.O.
Time limit output indicator
Operation/Power indicator
※ If power is cut or the RESET terminal is short-circuited, the timer will be reset.
※ If the INHIBIT terminal is short-circuited during a time limit operation, the time will stop.
※ In case of F, F1 output operation mode, setting time should be over 100ms.
If not, it may cause abnormal output operation due to under 100ms of setting time.
64.5
15
50
Panel cut-out
Min. 65
20
5
Min. 65
45
+0.6
0
15
21
31
[t: Setting time, t=t1+t2, t>t-a]
t
t1
t2
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
t
t
t-a
t
t1
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
t
t
t-a
t
t1
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
t-a
t-a
t
t1
t2
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
t
t
t-a
t1
t2
t-a
t
t-a t-a
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7
t
t
t
t-a
t-a t1
t2
Power 2-10
START 2-6
INHIBIT 2-5
RESET 2-7

Specifications

(unit: mm)
Model
AT11DN-
Function
Multi Function Timer
Control time setting range
※1
0.05 sec. to 100 hour
•100-240VACᜠ 50/60Hz, 24-240VDCᜡ universal •24VACᜠ 50/60Hz, 24VDCᜡ universal
Power supply
• 12VDCᜡ
Allowable voltage range
90 to 110% of the rated voltage
•Max. 3.5VA (100-240VACᜠ) ,
Max. 1.5W (24-240VDCᜡ)
Power consumption
•Max. 4VA (24VACᜠ),
Max. 1.5W (24VDCᜡ)
•Max. 1W (12VDCᜡ)
Return time
Max. 100ms
Time operation
Signal ON Start
Min. input signal width
START, RESET, INHIBIT: Min. 50ms
45
+0.6
0
START, RESET, INHIBIT: [No-voltage input] - Short-circuit impedance: Max. 1kΩ,
Input
Residual voltage: Max. 0.5VDC, Open-circuit impedance: Max. 100kΩ
Control
Contact type
Time limit DPDT (2c)
output
Contact capacity 250VACᜠ 5A resistive load
Relay
Mechanical
Min. 10,000,000 operations
life cycle
Electrical
Min. 100,000 operations (250VAC 5A resistive load)
Repeat error
Max. ±0.2% ±10ms
Setting error
Max. ±5% ±50ms
Voltage error
Max. ±0.5%
Temperature error
Max. ±2%
Insulation resistance
100MΩ (at 500VDC megger)
Dielectric strength
2,000VAC 50/60Hz for 1 minute
Ambient temp.
-10 to 55℃, Storage: -25 to 65℃
Environ-
ment
Ambient humid.
35 to 85%RH, Storage: 35 to 85%RH
Approval
Accessory
Bracket
Weight
※2
Approx. 132.2g (approx. 85g)
※1: Refer to time specifications for control time setting range by model.
※2: The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
2. 12VDC, 24VDC, 24VAC power supply should be insulated and limited voltage/current or Class 2, SELV power
t2
supply device.
3. When supplying or turning off the power, use a switch or etc. to avoid chattering.
4. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
5. In order to block peripheral current, use isolation transformer which of secondary part is not grounded as (Figure 1)
to supply power to the external input device.
(Figure 1)
START
RESET
INHIBIT
< Sensor >
t2
Isolation
<External sensor
Rectification
transformer
circuit
6. In order to avoid leakage current flowing, connect resistance and condenser as (Figure 3).
If connect as (Figure 2), it may cause malfunction due to leakage current.
(Figure 2)
(Figure 3)
Leakage
current
R
Power
Power
T
Timer
C
R
C
7. Do not connect two or more timers with only one input contact or transistor simultaneously.
8. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at
input signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
9. Change setting time, time range, operation mode or etc. after turning off the power of the timer.
10. This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specifications')
②Altitude max. 2,000m
③Pollution degree 2
④Installation category II
Major Products
Photoelectric Sensors
Temperature Controllers
Fiber Optic Sensors
Temperature/Humidity Transducers
Door Sensors
SSRs/Power Controllers
Door Side Sensors
Counters
Area Sensors
Timers
Proximity Sensors
Panel Meters
Pressure Sensors
Tachometers/Pulse (Rate) Meters
Rotary Encoders
Display Units
Connector/Sockets
Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, Co₂, Nd: YAG)
Laser Welding/Cutting System
AT11EN-
•Max. 4.3VA (100-240VACᜠ) ,
Max. 2W (24-240VDCᜡ)
•Max. 4.5VA (24VACᜠ),
Max. 2W (24VDCᜡ)
•Max. 1.5W (12VDCᜡ)
Instantaneous SPDT (1c)+Time limit SPDT (1c)
Approx. 134.7g (approx. 87.5g)
Power
power supply>
T
Timer
http://www.autonics.com
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu,
Busan, South Korea, 48002
TEL: 82-51-519-3232
DRW171149AA