POWER
LAMP
(OPTIONAL DRAIN PUMP)
REMOVE DRAIN PLUG
THEN SWITCH THE
MACHINE OFF TO START
THE AUTOMATIC
DRAIN PUMP CYCLE
PREPARATION
 CHECK THE DRAIN PLUG IS PUSHED FIRMLY IN PLACE AND FILTERS ARE PROPERLY SECURED.
 CHECK THE DETERGENT CHEMICAL ( RED ) AND RINSE AID CHEMICAL ( CLEAR ) SUPPLY TUBES - WITH FOOT VALVES - ARE
SUBMERGED IN SUFFICIENT PRODUCT.
 CHECK THE DOOR IS CLOSED AND PRESS THE POWER SWITCH - THE GREEN POWER LAMP WILL COME ON.
OPERATION
 REMOVE ALL DEBRIS FROM THE GLASSES TO BE WASHED BEFORE PLACING THEM INTO THE BASKET.
 CLOSE THE DOOR - PRESS THE CYCLE START SWITCH - THE CYCLE LAMP WILL COME ON.
 AT THE END OF THE CYCLE THE WASH CYCLE LAMP WILL GO OUT - OPEN THE DOOR AND PULL OUT THE BASKET.
 ALLOW EXCESS WATER TO RUN OFF BEFORE REMOVING.
ROUTINE MAINTENANCE
 AT THE END OF A SESSION TURN OFF THE POWER SWITCH. DO NOT REMOVE THE FILTER AT THIS STAGE.
 REMOVE THE DRAIN PLUG - THE WASH TANK WILL EMPTY -
(MACHINES FITTED WITH DRAIN PUMP WILL AUTOMATICALLY START TO PUMP THE WATER OUT).
 COLLECT THE DEBRIS AND REMOVE FROM THE WASH TANK.
 CLEAN AROUND THE WASH TANK - DOOR SURROUNDS AND HINGES WITH AN 'ADDIS'' TYPE WASHING UP BRUSH AND CLEANING
CLOTH.
 DO NOT USE CHLORIDE OR BLEACH CONTAINING BASED CLEANING SOLUTIONS OR ABRASIVES WHEN CLEANING THE WASH TANK.
 TAKE OUT THE MAIN FILTER - CLEAN THOROUGHLY AND REPLACE .
 DO NOT ALLOW DEBRIS TO GO DOWN THROUGH THE FIXED FILTER AND OUTLET HOLE AS THIS MAY DAMAGE YOUR MACHINE.
 REGULARLY CHECK RINSE JETS AND WASH JETS ARE CLEAR OF DEBRIS OR LIME SCALE - REMOVE IF NECESSARY BY UNSCREWING
THE RINSE ARM NUT THAT HOLDS THE RINSE ARM IN PLACE - REMOVE THE RINSE PIN THAT HOLDS THE WASH ARM IN PLACE - CLEAN
BOTH THOROUGHLY AND REASSEMBLE.
WATER SOFTENER
 REMEMBER TO REGENERATE THE EXTERNAL WATER SOFTENER IF FITTED REGULARLY. ENSURE THAT THE WATER VALVES ARE
TURNED BACK ON TO SUPPLY THE MACHINE WITH MAINS PRESSURE SOFTENED WATER.
RINSE
ARM
RINSE JETS
WASH ARM
SERVICE CALLS TO RECTIFY FAULTS CAUSED BY `THE LACK OF ROUTINE MAINTENANCE` WILL BE CHARGED FORAND YOUR WARRANTY MAY BE AFFECTED
OPERATING AND MAINTENANCE INSTRUCTIONS
SXG45 D / SXG50 D
WASH CYCLE
LAMP
POWER
CYCLE START
SWITCH
SWITCH
RINSE ARM NUT
RINSE PIN
WASH JETS
FOOT VALVES FOR
CHEMICAL
CONTAINER TUBES
www.directcatering.co.uk
MACHINE READY
LAMP
DRAIN PLUG
MAIN FILTER
FIXED FILTER
OUTLET HOLE