DynaQuip WaterCop WPM Manual del propietario y manual de instalación - Página 6
Navegue en línea o descargue pdf Manual del propietario y manual de instalación para Sistemas de control DynaQuip WaterCop WPM. DynaQuip WaterCop WPM 16 páginas.
FCC Information
This equipment has been tested and found to comply with the limits for a Class 8
digital device, pursuant to part 15 of the FCC Rules . These limits are designed to
provide reasonable protection against harmful interference in a residential installation .
This equipment generates, uses, and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications . However, there is no guarantee that interference will not occur in a particular
installation . If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
•
Reorient or relocate the receiver
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected
•
Consult the dealer for help
Operation is subject to the following two conditions:
1 . this device may not cause interference
2 . this device must accept any interference, including interference that may cause undesired
operation of the device
System Quick Reference Setting and Status
Valve is open and all components
WATERCOP
NORMAL
functioning properly .
WATERCOP
Water was turned off via local controls .
WATER IS OFF
!ALARM!
Wireless Sensor #1
water and turned the valve off .
SEN #1 WET 2
Hardwired Sensor
!ALARM!
Panel detected water and turned the
WIRE PANEL WET
valve off .
!ALARM!
Sensor #2
temperature was too low .
SEN #2 TEMP 1
Probe on Sensor #3
ALERT
**
**
Water is still on . Probe needs to be checked
SEN #3 SHORT 2
and repaired to allow proper function .
Probe 2 on Sensor #2
ALERT
**
**
Water is still on . Probe needs to be repaired
SEN #2 OPEN 3
or replaced to allow proper function .
ALERT
Battery in Sensor #2
**
**
to be replaced .
SEN #2 LOW BAT
ALARM
Battery in Sensor #2
**
**
function properly . Valve is closed .
SEN #2 DEAD BAT
If Safe Mode is enabled
POWER RESTORED
Power was lost and restored .
SAFE MODE CLOSED
Valve closed for safe mode .
Wireless Sensor #3
ALARM
**
**
on the rope sensor or high pressure in
SEN #3 WET 4
the line .
6
(Probe 1) detected
from Water Control
has detected ambient
(Probe 2) is shorted .
is cut or disconnected .
is low and needs
is so low it won't
has detected water
RESET WATER CONTROL PANEL
TO FACTORY SETTINGS:
Hold MODE – Press and hold OPEN until the display
reads: CONTINUE = OPEN DEFAULT = CLOSE –
Release first the OPEN button, then release the MODE
button then Press CLOSE .
This will delete all sensors and activate Safe Mode (if
enabled) .
TO ADD WIRELESS SENSORS:
Press MODE twice (DEVICE ADD) on WaterCop® Pro
Water Control Panel
Press CLOSE (DEV #1 ID=)
Press and hold the LEARN button (SEN #1 SHORT 2)
Release LEARN button (SEN #1 OK!)
Press MODE
Press CLOSE (DEV #2 ID=)
Repeat for all Sensors . When finished, press MODE
twice to return to WaterCop® NORMAL
TO REMOVE WIRELESS SENSORS:
Press MODE three times (DEVICE REMOVE)
Press CLOSE to scroll to device to be removed
Press OPEN to remove that device
Press MODE to return to WaterCop® NORMAL
TO CHECK SENSOR
STATUS:
Press MODE while valve is open
Scroll using CLOSE
Press MODE three times to return to
WaterCop® NORMAL