DC MONT DC-MPPT-MPK2-60A Manual del usuario - Página 7

Navegue en línea o descargue pdf Manual del usuario para Controlador DC MONT DC-MPPT-MPK2-60A. DC MONT DC-MPPT-MPK2-60A 17 páginas. Mppt controller

DC MONT DC-MPPT-MPK2-60A Manual del usuario
1. Battery Setting
In this interface, you can choose battery type,
system voltage, and set up battery parameters
(absorption voltage, absorption duration, over
voltage disconnection voltage, etc.).
Load working mode
By switching on "Load working mode", you can
choose other working modes for the load, i.e.
(1) light control mode, (2) dual time period
control mode or (3) time period control mode.
2. Load Setting
In this interface, you can choose normal
working mode or other working modes.
Normal
By switching on "Normal", the load will work for
24H per day.
(1) Light control
As the interface shows, the load will turn on
when the voltage of the solar panel decreases
to 5V at sunset and turn off when the voltage
reaches 6V at sunrise.
MONT