Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
BJ
-
❶ Feature
No mark: General type
G: Transparent glass sensing type
(Diffuse reflective type )
N: Micro spot type
(Narrow beam reflective type)
❷ Sensing distance
Number: Sensing distance (unit: mm)
Number+M: Sensing distance (unit: m)
❸ Sensing type
T: Through-beam
P: Polarized retroreflective
D: Diffuse reflective
B: BGS reflective
N: Narrow beam reflective
Sold Separately
• Reflector: MS Series
• Retroreflective tape: MST Series
• Bracket B: BJ BRACKET B
Cautions during Installation
• Be sure to install this product by following the usage environment, location, and specified
ratings. Consider the listed conditions below.
- Installation environment and background (reflected light)
- Sensing distance and sensing target
- Direction of target's movement
- Characteristic curves
• When installing multiple sensors closely, it may result in malfunction due to mutual
interference.
• BGS reflective : If the sensing target has a glossy surface or high reflection, tilt the sensor with
an angle from 5 to 10 degrees and install it. Get rid of the effect of background object on the
sensing performance.
• Narrow beam reflective: Mount the sensor tilted at an angle from 0 to 15 degrees for stable
copper wire detection.
Tilt angle
• For installation, tighten the screw with a torque of 0.5 N m. Mount the brackets correctly to
prevent the twisting of the sensor's optical axis.
• Do not impact with a hard object or bend the cable excessively. That could decrease the
product's water resistance.
• Use this product after the test. Check whether the indicator works appropriately for the
positions of the detectable object.
Through-beam
Retroreflective
Sensor - Reflector:
At least 0.1 m apart,
Emitter - Receiver:
install to face each other
Install to face each other
(parallel with the sensing
side of the unit)
-
-
❹ Power supply
D: 12 - 24 VDCᜡ
❺ Output
T: Solid state (transistor)
❻ Connection
No mark: Cable type
❼ Control output
No mark: NPN open collector output
P: PNP open collector output
Reflective
Sensor - Sensing target:
Install to face each other
(parallel with the sensing
side of the unit)
BGS reflective :
Recommend horizontal /
back and force movements
of sensing target
Setting Operation Mode
• Be sure to set the mode before power-on.
• Use the offered adjustment screwdriver. Do NOT turn with excessive force to prevent
product damage.
L: Light ON mode
Operation Timing Chart and Indicators
■ Light ON mode
Received
light
Through-
beam
Reflective
• In Dark ON mode, the waveforms are reversed.
• Operation indicator and transistor output differ from the sensing method.
Connections
■ Emitter
Brown
Blue
■ Receiver, Polarized retroreflective/Diffuse/BGS/
Narrow beam reflective type
Brown
LOAD
Black
NPN
Max. 100 mA
Blue
Circuit
■ NPN open collector output
OCP
SCP
• OCP (over current protection), SCP (short circuit protection)
• If short-circuit the control output terminal or supply current over the rated specification, normal control signal is
not output due to the protection circuit.
D: Dark ON mode
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
12-24 VDCᜡ
Brown
Max. 100 mA
Black
PNP
12-24 VDCᜡ
LOAD
Blue
■ PNP open collector output
LOAD
OCP
SCP
Max. 100 mA
Stable
light ON area
Unstable
light ON area
Operation
level
Unstable
light OFF area
Stable
light OFF area
Stability indicator
(green)
Operation indicator
(red)
Transistor output
Operation indicator
(red)
Transistor output
12-24 VDCᜡ
Max. 100 mA
LOAD