Autonics ARD-DO08RE Manual

Navegue en línea o descargue pdf Manual para Sistemas de E/S Autonics ARD-DO08RE. Autonics ARD-DO08RE 8 páginas. Devicenet digital remote i/o
También para Autonics ARD-DO08RE: Manual (8 páginas)

Autonics ARD-DO08RE Manual
ARD-D Series
DeviceNet Digital Remote I/O
Features
● Automatic communication speed recognition
: Enables to recognize communication speed automatically
when connecting with master
● Network Voltage monitoring
: If PV is lower than SV, enables to receive error flag for
network power monitoring as Explicit message.
● Additional expansion units
- Standard terminal block type: Connectable up to 3 expansion units
- Sensor connector type: Connectable up to 7 expansion units
- Expandable I/O points up to max. 64 points for Standard terminal type,
sensor connector type
● Reading the number of expansion units
: Reads the number of connected expansion units
● Reading model name: Reads the connected model name
of connected units (sensor connector type)
● Reading the unit specifications: Reads the specifications of connected units
Please read "Caution for your safety" in operation
manual before using.
Ordering Information
AR
D
D
I
I/O type
Digital/Analog
Network
Item
※ 1: Sensor connector type (ARD-
※ 2: Sensor connector (CNE-P04- ) is sold separately. It is compatible with e-CON connector.
※ 3: It is only for an expansion unit of sensor connector type.
※ 5: For ARD-A Series as analog type, refer to S-13 page.
Model
Model
Terminal type
Basic unit
ARD-DI08A
ARD-DI16N
ARD-DI16P
ARD-DO08R
Standard
terminal block
ARD-DO08S
type
ARD-DO16N
ARD-DO16P
ARD-DX16N
ARD-DX16P
ARD-DI08N-4S
Sensor
ARD-DI08P-4S
connector
ARD-DO08N-4S
type
ARD-DO08P-4S
DeviceNet Digital Remote I/O
Terminal
08
A
E
4S
block
Structure
※ 1
I/O specification
I/O point
-4S) model is only for NPN, PNP I/O specifications.
Specification
Expansion unit
ARD-DI08AE
75-250VAC input 8-point (13mA/point)
ARD-DI16NE
10-28VDC NPN input 16-point (10mA/point)
ARD-DI16PE
10-28VDC PNP input 16-point (10mA/point)
ARD-DO08RE
Relay output 8-point (2A/point), Life cycle of contact: 100,000 times
ARD-DO08SE
SSR output 8-point (1A/point)
ARD-DO16NE
NPN output 16-point (0.5A/point)
ARD-DO16PE
PNP output 16-point (0.5A/point)
ARD-DX16NE
10-28VDC NPN input 8-point (10mA/point), NPN output 8-point (0.5A/point)
ARD-DX16PE
10-28VDC PNP input 8-point (10mA/point), PNP output 8-point (0.5A/point)
ARX-DI08N-4S
10-28VDC NPN input 8-point (10mA/point)
ARX-DI08P-4S
10-28VDC PNP input 8-point (10mA/point)
ARX-DO08N-4S
NPN output 8-point (0.3A/point)
ARX-DO08P-4S
PNP output 8-point (0.3A/point)
※ 2
No-mark
Standard terminal block type
4S
Sensor connector type (4pin)
No-mark
Basic unit
※ 4
E
Expansion unit
A
AC voltage
N
NPN open collector
P
PNP open collector
08
8 points type
16
16 points type
I
Input type
O
Output type
X
I/O mixed type
D
Digital type
※ 5
A
Analog type
D
Basic unit (DeviceNet type)
※ 3
X
Expansion unit (use in DeviceNet/Modbus)
AR
Autonics Remote I/O
※ 4: It is only for an expansion unit of standard terminal block type.
Standard terminal
block type
Sensor connector type
R
Relay
S
SSR
S-5
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software