Dynascan PMR446 Manual de instrucciones - Página 10

Navegue en línea o descargue pdf Manual de instrucciones para Transceptor Dynascan PMR446. Dynascan PMR446 16 páginas. Handheld transceiver
También para Dynascan PMR446: Manual de instrucciones (11 páginas), Manual de instrucciones (10 páginas)

Dynascan PMR446 Manual de instrucciones
Menu 5: Transmit overtime timer (TOT):
Time out timer refers to set the limited time each transmitting. It may automatically stop
transmitting if reach the limited time, regardless you press the [PTT], the transceiver may
issue the "time out timer" at the same time.
Settings: 15 to 600 seconds, step 15 seconds.
Default: 90 seconds.
Note:
- There is a 10 second TOT punishment when the transmitting time beyond the
limited time, it is invalid to press the [PTT]. The TOT punishment is effective for
the keypad transmission and VOX transmission.
Menu 6: VOX function (VOX):
Settings: Off/1 to 5 seconds.
Default: Off.
Notes:
- VOX function is usable for the selected operation channel.
- In receiving state, the VOX function is off.
Menu 7: Bandwidth (W/N):
This menu is not available to the user.
Menu 8: Voice guide (VOICE):
By means this function, you will hear a voice prompt when performing any operation on the
transceiver.
Settings: OFF/ENGLISH.
Default: ENGLISH.
Menu 9: Time over alarm (TOA):
This function notifies you before reaching the maximum transmission time (TOT).
Settings: OFF/1 to 10 seconds.
Default: 5 seconds.
Menu 10: Beep function (BEEP):
This function alerts you with a "beep" when operate the transceiver, operation error or
fault.
Settings: On/Off.
Default: On.
Menu 11: Busy channel lockout (BCL):
This function locked the transmission while the channel is busy.
Settings: ON/OFF.
English - 10 -