Autool CT-200 Manual - Página 9

Navegue en línea o descargue pdf Manual para Equipos de limpieza Autool CT-200. Autool CT-200 18 páginas. Injector cleaner & tester
También para Autool CT-200: Manual del usuario (14 páginas), Manual del usuario (14 páginas)

Autool CT-200 Manual
2) Press Left or Right Arrow key to set up injecting time (account time)
3) The next steps are the same as what listed in 02 Idle Speed Test.
NOTE:
To simulate the injecting condition after working for a certain times in Idle
speed

09 Medium Speed Spray Value Test

1) Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2) The next steps are the same as what listed in 08 Idling Spray Value Test.

10 High Speed Spray Value Test

1) Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2) The next steps are the same as what listed in 08 Idling Spray Value Test.
NOTE:
1. Check the deviation of the spray value: test the spray value in different
rpm, check the spray value in different measuring cylinder, the
deviation should not exceed 2% or refer the specification of the injector.
2. Leakage test: leakage should not occur within 1 minute under 0.3MPA
system pressure.

3.3 Reverse Flushing

The flush fluid go into the injector through its outlet and go out through
its inlet, so that it can clean the filth inside, which can not be cleaned by
normal way.
- - 9 - -