Dynaset HPW-DUST Manual de instrucciones - Página 7

Navegue en línea o descargue pdf Manual de instrucciones para Equipos de construcción Dynaset HPW-DUST. Dynaset HPW-DUST 20 páginas. High pressure dust suppression systems

7
Valve kit for Open centre hydraulic systems includes pressure compensator PV-SAE pos. 2.1. When installing
to close centre hydraulic system, concerned pressure compensator is not required.
HYDRAULIC VALVE KIT for a DUAL WATER CIRCUIT SYSTEM (DWC) includes following components:
PRESSURE REDUCING VALVE 2.2, FLOW LIMITING VALVE 2.3 and SOLENOID VALVE 2.4.
In OC-hydraulic systems, HPW-pump is operated under constant hydraulic pressure. The output water flow and
eventually hydraulic flow is rated by the size of installed water nozzles.
The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression.
2.1
B
LS
P
A
OC-HYDRAULICS
HYDRAULIC VALVE KIT for SINGLE WATER CIRCUIT (SWC) SYSTEM provides two separate hydraulic flows,
one for both power level of dust suppression.
On / Off -valve
2.3
PC-SAE 3/4"
2.4
Solenoid valve
2/2 NC
3
2.2
2
1
Flow limiting
valve
Control valve kit for single water circuit system (SWC).
HPW-DUST HIGH PRESSURE SUPPRESSION SYSTEMS

A HYDRAULIC ACTUATOR VALVE KIT

T
2.3
HPW200 dust double-DWC, D200105350
P
Solenoid-valve
Pressure relief valve
T
April 2014 JLe
2.2
Pressure reducer
7-210
2.3
Flow limiter R3/4 u s
2.4
LS
P