5. Maintenance

5.1 Overview

It is recommend that the vacuum cleaner be checked regularly to extend the
service life.
Note:
During the maintenance and repair process, the power supply of the vacuum
cleaner must be disconnected. Wear protective equipment such as safety shoes,
protective gloves, protective masks, etc.

5.2 Daily Inspection

Check that the accessories connected to the vacuum cleaner are intact, without
any cracks, etc. In addition, make sure that the air can flow without obstruction. If
necessary, the hose can be replaced.
Check the dust cleaning device: check whether the suction pipes in the barrel are
damaged and whether some other impurities are also sucked in; check whether the
sealing ring and the sealing strip are intact and replace them if necessary. Check
whether the cartridge barrel cover is sealed on the sealing surface of the cartridge
barrel.
Check the cyclone separator: lower the vacuum cleaner to transport position,
disassemble locking
buckle and take off cyclone barrel cover. Use a flashlight to illuminate the cyclone
separator. The surface of separator should be dull. If there is a light spot on the surface,
the separator is blocked and need to be cleaned.
Check the filter barrel: lower the vacuum cleaner to the lowest transport position,
disassemble locking buckle and remove the filter barrel
if it is covered with
dust, if it is, put it in a
plastic bag for vibration cleaning.
Check the internal hose: check whether the internal hose is intact, and replace the
hose if
necessary.
Check draught fan: remove the fan cover, check whether the fan is blocked by dust,
and clean it if necessary. While the machine is running, listen carefully for any harsh
sound coming from inside the fan cover.
Check the tightness of the accessories: check all bolts and screws for tightness
every six months.
Note:
Press emergency stop and disconnect the power before checking. When lowering
the vacuum cleaner to the transport position, wear protective gloves to avoid the risk
of crushing. When carrying out the inspection, wear a protective mask to avoid
inhalation of dust.
cover.
Take out the filter to see

5.3 Cleaning

5.3.1 Clean cyclone separator

Press the emergency stop button and pull out the power.After stopping the
machine, lower the cyclone barrel to the transport position and loosen the three bolts
on the cyclone barrel.(Figure 1)
Remove the cover from the integrated bucket, remove the suction hose from the
cyclone, illuminate it with a flashlight, check if the inside is blocked, and clean the
inside of the cyclone if necessary.

5.3.2 Clean the filters

Enter the manual cleaning
mode,
and after repeated many times, the filter element
can be
cleaned.
16