Autopilot ECP0312 Manual de solución de problemas
Navegue en línea o descargue pdf Manual de solución de problemas para Filtro de piscina Autopilot ECP0312. Autopilot ECP0312 2 páginas.
Level
Salt
Ideal 3,500 ppm (mg/L)
20 gpm (4.5 m
Water Flow
Model Output
CS30
CS40
CS50
All cells draw 6.5 ‐ 7.5 amps
Rated at 3,500 ppm salt
Color
Salt LED Indicator:
Green
Green
Red
Red
Cell LED Indicator:
Green
Red
Flow LED Indicator:
Green
Red
Manual Readings (no PoolSync®): Press the Up Arrow 5 times, then press the Down Arrow 5 times.
The following will be displayed
‐ Cell size [CS30, CS40, or CS50]
‐ Water Temerature [F.°]
‐ Salt Concentration [ppm]
‐ Current and Voltage
Immediate Salt Check (with PoolSync®):
1. Open the app and select the ChlorSync under the EQUIPMENT options
2. Press the 3‐dot menu on the ChlorSync page
3. Select SALT, a pop‐up window will prompt to REMEASURE SALT.
4. Select Ok.
Notes:
֎ The displayed salt level is updated as follows
‐ When the power is restored or when flow is established
‐ Every 12 hours after power is applied or flow is established if salt levels are above 2,300 ppm (mg/L).
‐ Every 60 minutes if salt level is < 2,300 ppm (mg/L)
֎ A er the purifier output level is set using the arrow bu ons, the unit will automa cally make fine output adjustments as the water temperature
fluctuates. This patented temperature compensation feature will adjust output depending on water temperature.
֎ When the water temperature falls below 55°F (12.8°C), chlorine produc on is reduced to 1% to prevent over chlorina on. Normal produc on will
resume when the water temperature rises above this level.
Warning ‐ Failure to heed the following may result in permanent injury or death.
RISK OF ELECTRICAL SHOCK ‐ All electrical connections should be made by a licensed electrician or certified electrical contractor.
RISK OF ELECTRICAL SHOCK ‐ Disconnect all AC power when installing or servicing this system. Follow all state, local, and National Electrical
Code(s) (provincial and Canadian Electrical Code(s) if applicable). Use copper conductors only.
RISK OF ELECTRICAL SHOCK ‐ Before plugging or unplugging the unit to the power center, first switch off the AC power to the power center.
Caution ‐ Failure to heed the following may result in equipment damage.
Connecting 230 Vac to a unit that has been configured to 110‐120 Vac will result in permanent damage to the unit. Damage due to incorrect
wiring is not covered under the warranty.
ChlorSync
‐ Troubleshooting Guide
®
Min.
Max.
2,700 ppm (mg/L)
5,000 ppm (mg/L)
3
/hr.) 80 gpm (18.2 m
Production/Day
1.1 lbs/0.50 kg
1.4 lbs/0.64 kg
1.7 lbs/0.77 kg
INDICATOR LIGHTS
Status
Display
On (solid)
Normal
Flashing
Normal
On (solid)
Lo SALt
Flashing
Add SALt
On (solid)
Normal
CLn CELL or CLn CELL
Flashing
SOOn
On (solid)
Normal
Flashing
no FLo
3
/hr.)
Indication
Salt Level = 2,700 ‐ 5,000 ppm (mg/L) ‐ Recommended
Salt Level > 5,000 ppm (mg/L) ‐ High Salt
Salt Level = 2,300 ‐ 2,700 ppm (mg/L) ‐ Low Salt
Salt Level < 2,300 ppm (mg/L) ‐ Salt Addition Required
Normal Operation
Low Conductivity/High Current (Scale formation, Low Salt,
Etc.) or Open Cell
Normal water flow detected
Low or No Water Flow detected
For full manual use
QR code
Chlorine
Generating
Status
ON
ON
ON
OFF
ON
OFF
ON
OFF