- Notifications are needed for the operation of Therminal application. If user sends
SMS manually, notifications can be turned off by the means of RCP settings 7.3.8
and 7.4.8, or via settings of GSM modem (see User Manual for details).

Troubleshooting

If a run-time error occurs with the heater, RCP Can will inform you by the built-in
and additional LEDs blinking about the error code. When Plug-n-Play cable is
used for connection, additional red LED is placed inside the housing of OBD-II
connector of Plug-n-Play cable and stays visible from the driver's side.
The number of LED's flashes corresponds to the error code. See table 4 for the
codes description and possible solutions.
Error
Error
Code
Description
1
Wrong heater
configuration
3
Battery level
is low
4
Time limits
exceeded
9
Possible Reasons of
Error Appearance
The heater is not
activated in DIS
Outer temperature is
upper than +15 Celsius
degrees
Fuel level in the tank is
close to empty ("Fuel
Low" warning indicator
is lighting in DIS)
The heater is blocked
after 3 unsuccessful
starts
The module has
determined that the
battery voltage at the
heater startup or during
the heater operation is
below the specified
settings 3.1 и 3.2
Time limit for
autonomous operation of
the heater is achieved
(with active setting 1.1)
Solutions
Configure the heater by Volvo
car dealer equipment
The heater works only with
temperatures below +15°C. It
is the heater manufacturer's
restriction
Refuel your vehicle
Try to start the heater from
DIS menu. If it not started to
burn, make a diagnostics of
the heater.
Charge vehicle's battery with
special charger (or start engine
to charge) or cancel 3.1/3.2
module's settings
Run the engine or cancel 1.1
module's setting
Table 4