An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached
to a Controller 6000) or a Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI).
HBUS Reader connection:
Note: To terminate an HBUS Reader, connect the Orange (HBUS Termination) wire to the Green
(HBUS A) wire.
Cardax IV Reader connection:
5.
Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
the top, press the bottom of the facia assembly down into the bezel.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the bottom of the bezel to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly tightened.
7.
Removal of the facia assembly is a simple reversal of these steps.
3E4237 Gallagher T15 Reader | Edition 11 | February 2022
Copyright © Gallagher Group Limited
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
Building cable
Reader tail
Facia
Fit screw to secure facia to bezel
HBUS Reader terminated:
Connection
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue