Gallagher C500615 Notas de instalación - Página 5

Navegue en línea o descargue pdf Notas de instalación para Instrumentos de medida Gallagher C500615. Gallagher C500615 8 páginas. Smb monitoring kit

Gallagher C500615 Notas de instalación
3. Inserting the PSTN Dialer
The Gallagher PSTN Dialer is supported by the Gallagher Controller for both Contact ID
transmission and remote/PPP dial-up situations.
The dialer is housed in the same cabinet as the controller and is mounted on top of the
controller via the serial port. Secure the dialer to the controller using the 2 screws supplied.
With a dialer mounted on the controller, the controller's run LED is still readily visible.
4. Connecting the Wiring Loom
The wiring loom is used to join the Alula to the Dialer and the D8 module.
Alula
Connect the red to 12V, black to GND, wht/blue to RING, and blue/wht to TIP. Secure the
wireset tightly to the Alula's enclosure using the cable tie that is supplied in the wireset kit.
This acts as a strain relief.
PSTN Dialer
Connect the red to VIN, black to 0V, wht/blue to RING IN, and blue/wht to TIP IN.
D8 Module
Connect red to Out7 "+", and black to Out7 "-". Set jumper JP7 to position 2 (for 12V output
instead of position 1's 24V).
4. Setting Network Communication Path
Connecting via ethernet
Connect an ethernet cable from the Alula's ethernet port to the customer's network and
ensure the ethernet's LED is on.
Connecting via cellular
Verify the cellular LED is on and verify signal strength. A minimum of two signal bar LEDs is
recommended.