INSTALLATION

POWER OVER ETHERNET CABLING PLAN

Galleons SignalClock requires a connection to a PoE enabled network so it can source power in
compliance with IEEE 802.3af.
PoE power is commonly used to power devices such as wireless Access Points and IP Telephones;
it is usually injected into the LAN using either PoE enabled Ethernet switches or a Power Injector.
Consult with your IT Administrator regarding the PoE equipment on your network.
SMALL SCALE INSTALATIONS
Single port PoE power injectors are the best means of power for a demonstration system or a
small scale deployment.
A power injector is typically installed in the communications room, and passes Ethernet
communications through while also injecting power in accordance with the IEEE 802.3af standard.
Note - A power injector requires a connection to AC power and may be connected to a battery
backed uninterruptable power supply (UPS).
Galleon Systems offers a single port PoE injector for sale to support demonstration systems. For
more information on these please call our Sales Team on 0121 608 7230.

SITES WITH POE ENABLED NETWORK EQUIPMENT

Note: Before you configure your unit, make sure you've chosen an area that's appropriate to mount the
clock later, taking into account how long you require the leads to be.
Sites that are already equipped with a PoE enabled network are most likely already compatible
with the SignalClocks Digital Clock.
If you have a PoE network simply connect the clock to the PoE enabled port on your hub/switch.
The Digital Clock will then automatically request and receive power from a PoE enabled switch
that conforms to the IEEE 802.3af standard.
If the site plan calls for a significant number of clocks to be powered from a single piece of
network equipment, it may be useful to verify that that piece of equipment can deliver the
necessary power. Some PoE enabled switches cannot deliver the full IEEE 802.3af power of 550ma
per port or may require certain power options to do so.