DCS RGSC-305BK Manual de instalación - Página 10
Navegue en línea o descargue pdf Manual de instalación para Gamas DCS RGSC-305BK. DCS RGSC-305BK 17 páginas. Professional 30” self clean gas range
ELECTRICAL/GAS CONNECTIONS
STEP 4: ELECTRICAL CONNECTIONS
Receptacle Box
Cover Plate
Three
Prong
Plug
Three Prong
Receptacle
FIG. 11
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with
polarized parallel blades). It must be plugged into a mating grounding type receptacle, connected to
a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the
responsibility and obligation of the installer or user to have the existing receptacle changed to a
properly grounded and polarized receptacle in accordance with all applicable local codes and
ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle
replacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONG
SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED (See Fig. 11).
STEP 5: GAS
Verify the type of gas supplied to the location. The range is shipped from the factory set up and
adjusted for natural gas or LP (propane), depending on specific model ordered. The unit cannot be
converted.
NATURAL GAS REQUIREMENTS
Connection: 1/2" N.P.T. Minimum 5/8" dia. flex line. Pressure: 6" to 14" W.C.
L.P. GAS REQUIREMENTS
Connection: 1/2" N.P.T. Minimum 5/8" dia. flex line. Pressure: Supply pressure must be 11" to 14" W.C.
A regulator is required at the L.P. source to provide a maximum of 14" W.C. to the range regulator.
POWER REQUIREMENTS
120 VAC, 60 Hz., single phase. 4 Amp. Max. (Use 15
Amp. Circuit)
Always disconnect electric supply cord from the
wall outlet or service disconnect before servicing
this appliance. Observe all governing codes and
ordinances when grounding, in the absence of
which, observe National Electrical Code ANSI/NFPA
No. 70-1990.
9