AFJ Instruments LT32C/10 Manual de instrucciones - Página 17
Navegue en línea o descargue pdf Manual de instrucciones para Hardware de red AFJ Instruments LT32C/10. AFJ Instruments LT32C/10 18 páginas. Artificial mains network (lisn)
7. select the line to be measured using the LISN front panel pushbutton;
8. report the measured impedance in the following table, according to the related frequencies. The last
two columns carry the CISPR 16-1-2 impedance limits
f [MHz]
Z
[Ω]
N
0.01
0.02
0.08
0.15
0.30
0.50
0.80
1.00
2.00
3.00
8.00
15.00
20.00
30.00
NOTE: The connection between measuring instrument and EUT power plug is made using a custom
adapter. This fixture is made by a standard male power plug, and two coaxial connectors. The central
wires of the coax connectors have to be soldered to the power wires (L, N), while the coax shields
have to be soldered to the Protective Earth conductor.
It is important to keep all connections within the adapter as short as possible, to avoid measuring
errors at high frequency.
AFJ LT32C/10 LISN - Operating Manual - rev. 3.8 / 2019-01
Z
[Ω]
Z
[Ω]
L1
L2
Distributed by:
Reliant EMC LLC
3311 Lewis Ave, Signal Hill CA 90755,
408-916-5750, www.reliantemc.com
Z
[Ω]
Ref. -20%
L3
4.29
5.80
16.95
26.17
34.60
37.77
39.08
39.41
39.85
39.93
39.99
40.00
40.00
40.00
Ref. +20%
6.43
8.70
25.43
39.26
51.89
56.66
58.62
59.11
59.77
59.90
59.99
60.00
60.00
60.00