Indication
POWER
1. One or both HDSL lines
LED off
are no longer connected
between the COT and
RT. Verify the
connections at the RT
and COT.
2. The COT Line Unit fuse
F1 has blown.
3. The RT Line Unit power
supply has failed.
4. The COT HDSL powe r
supply has failed.
Indication
LOOP 1
1. The HDSL line is
(2) SYNC
attempting to synchronize
LED
with the central office unit
flashing or
or cannot detect the
off
HDSL signal from the
central office unit. This is
usually an indication that
there is a problem with
the HDSL circuit between
the COT and RT
(assuming the FAULT
LED is off ).
2. COLU and RTLU
incompatible i.e. one is a
T1 version and the other
is an E1.
LOOP 1
The HDSL line margin level
(2)
is below a preset level.
MARGIN
LED on
FAULT
Faulty FRL-772 RT Line
LED on
Unit.
TABLE 3. FRL-772 RT LINE UNIT TROUBLESHOOTING
Problem
a. Make the following measurement on the RT Enclosure backplane:
b. Make the following measurements on the COT Shelf backplane:
• -130 Vdc, ±10%, between A_HDSL_T1 and Chassis Ground
• 0 Vdc to +120 Vdc, between A_HDSL_T2 and Chassis Ground
(Note: Use B_HDSL_T1 and
B_HDSL_T2 for System #2)
Replace the fuse.
Replace the RT Line Unit.
Replace the COT Line Unit.
Problem
a) Verify the HDSL circuits are terminated properly and with the
b) Measure the loop resistance of each HDSL circuit (shorting the
See the previous discussion on the SYNC LED flashing or off .
Replace the RT Line Unit.
• 130 Vdc to 250 Vdc between A_HDSL_T and B_HDSL_T
correct orientation.
pair at the far end). The loop resistance must be less than that
shown in Table 1.
Section 363-772-100
Action
Action
Revision 01