K9 Partner Power Door Opener System with PowerTouch Remote Control
Installation: Electrical - Door Open Circuit
3) Install Door Open Circuit - Maximum output is 300mA
NOTE: Both button 'A' and 'B' can be wired so that either one will open the door.
A) Connect the red power wire directly to the battery. See diagram 11b (18" red wire not supplied)
B) Connect the other end of the power wire to the terminal marked
battery on the circuit breaker.
C) Connect the other terminal of the circuit breaker to the input terminal
S2 (silver) of the toggle switch. See diagram 11a
D) Connect the orange wire to terminal S1 (brass) on the toggle switch.
E) Connect the other end of the orange wire to terminal #87 on the relay.
Mount the relay near the receiver.
F) Connect the pink wire to relay terminal #86.
G) The other end of the pink wire is connected to the receiver channel 'B' output. (Channel 'A',
violet wire, may also be used to open door.)
H) Connect relay terminal #30, green wire, to the green wire on the actuator for pull. (Reverse wires
to change actuator to push)
I) Connect chassis ground for actuator motor using technique on page 10.
J) Connect ground required to illuminate status bulb in switch to relay terminal #85 on relay. Run
this ground through the proximity switch to disable motor when system is not active, switch is
Off or vehicle is in gear.
Diagram 11b - Door Open Circuit, Button 'B'
1
1
Red
2
2
Violet (A)
3
3
Pink (B)
4
4
Gr/Bk (-)
5
5
Yl/Bk (-)
Brown
6
6
7
7
Blue
Black
8
8
Gray Antenna Wire - 36" Long
Typical Current Draw is 100mA
Notes:
A) Auto reset circuit breaker is mounted in the
engine compartment next to the battery.
B) Most applications will use the 'pull' direction
of the actuator. To 'push', reverse the
green and blue wires.
4) Test mechanical and high current part of installation
A) Turn power switch On.
B) Unplug the connector from the receiver. Take a long wire (which has been stripped on both ends) and
connect one end to the battery +12vdc, and touch the other end of wire to relay terminal #86.
The relay should energize and the coil inside the relay should click. The output on terminal #30 is
+12vdc and will activate the actuator. *Ensure the pull of the actuator is straight. If it is not
straight, the actuator may bind and fail.
C) Connect the door latch. Using the long wire that is still attached to the battery +12vdc, touch the other
end of wire to relay terminal #86.
The relay should energize and the coil inside the relay should click. The output on terminal #30 is
+12vdc and will activate the actuator allowing the door latch to be pulled open. If the door does
not open, check the length of the actuator pull travel. If the required travel length is more than
3/4", change the installation design to allow a lever or spring to assist. Actuators lose pulling force
if the pull is over extended or more than 3/4".
WARNING!
If the receiver output wires are installed to the wrong polarity, the output will be damaged. For example:
if the channel 2 pink (+12) output wire is connected to a ground, a 'dead short' will occur when the button
is pressed. The output will test 'dead' and the trace may be burned or test 'high (On)' at all times.
Wiring Inspection
A) Check all wiring connections visually
B) Check the polarity of all wires
C) Tape off or remove all unused wires.
Ground
+12v
(-)
(+)
Bat Aux
Battery
10A - Auto Reset
Circuit Breaker
Red wire supplied
Optional - Both buttons will open the door.
Diagram 11c
Relay Schematic
30A - SPDT
Load (brass)
Orange Wire
18" Wire Not Supplied
On/Off Toggle
Switch, 15 Amps
S2
Red Wire
S3
Door Open Relay
30 Amp SPDT
Pink and/or violet wire
85
87a
87
Door Latch (open)
86
30
Actuator Motor
Manual C840.N2
Diagram 11a
Terminal View Detail:
On/Off Toggle Switch
S2
S1
S3
Ground (copper)
Black Wire
+12v (silver)
Red Wire
S1
Orange Wire
Black Wire
Optional Door
87
Motor Disable
Black
Switch
87a
86
85
30
(100mA)
Proximity
Blue
Switch
M
Green
GND
Pull
GND
Page -11-