1. Operation and maintenance

1.1. Device description

The tank is protected against corrosion by a ceramic enamel burned at 850°C. A large magnesium anode is an additional protective element. The tank is
insulated with ecological polyurethane foam, which reduces heat loss to minimum. The outer housing is made from steel and is coated with powder paint.
This layer tank is designed for operation with a dual function gas boiler and storage of domestic hot water. The tank acts as a buffer loaded from the top with
warm water, which does not mix with the cold water occupying the bottom section of the tank. This solution greatly enhances the comfort of using a dual
function boiler, resulting in a large amount of heated water in a short time. Thanks to its layered water distribution, small water consumption does not start
the boiler too often. This prolongs its life and allows the user to save gas.

1.2. Technical characteristics

The main part of the device is the tank, in which the water is heated. The tank is made from a sheet of steel which is then enamelled with a ceramic enamel
on the inside part of the tank. The connections of the tank are closed with corks and all are located at the top cover.

1.3. Scheme

5
6
7
10
11
7
6
© All rights reserved - Galmet Sp. z o.o. Sp. K.
307 mm
165 mm
2
1
12
600 mm
5
9
1
3
2
4
Ø500
13
8
1. Operation and maintenance
1. cold water inlet
2. cold water outlet (to boiler)
3. sensor to control the pump
4. magnesium anode on a 5/4" cap (under the top cover)
5. circulation connector
6. connector for hot water from boiler
7. domestic hot water outlet
8. drain
9. 3-stage circulation pump
10. switch
11. thermostat
12. thermometer
13. 5/4" plug for electrical set
Installation and Operating Manual - SG(S) Fusion