Product Installation Guidelines
INSTALLATION
INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these
installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements.
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of the
product.
1. Fit wall flange
−
Remove the maintenance tail from the body and
take the wall flange out of the packaging.
−
Ensure O-rings are secure in the rear of the wall
flange and slide over the maintenance tail.
Maintenance Tail
Body
3. Fit body
−
Check maintenance tail to ensure O-rings
are fitted correctly and in good condition to
prevent leakage.
−
Fit the body onto the maintenance tails
until it sits flush against them taking care
not to damage the O-rings.
© Galvin Engineering Pty Ltd
O-ring
Wall flange
2. Fit maintenance tail
4. Fit grub screws, indicator & testing
−
Fit the maintenance tail with wall flange to the wall
spud and fasten with the supplied 12mm Allen key.
We recommend using thread tape or equivalent to
ensure the connection does not leak.
−
Ensure the CliniLever
against the maintenance tail and then secure in
place with the supplied grub screws.
ALL TWO (2) GRUB SCREWS ARE FITTED
WITH SUPPLIED ALLEN KEY.
Screws are missing, contact us on 1300 514
074.
−
Once grub screws are secure, fit the water
temperature indicator.
−
Cold indicator must be blue, hot must be red
and warm must be yellow.
−
Open the regulating valve prior to turn the tap
on. Open the lever handle, inspect the tap and
check for any leaks.
Version 1, 16 August 2023, Page 3 of 5
Document No.: 001.00.10.31
Indicator
Grub screw
®
body is pushed firmly
ENSURE
If Grub