Galvin Engineering 49924 Manual de instalación - Página 3
Navegue en línea o descargue pdf Manual de instalación para Productos de fontanería Galvin Engineering 49924. Galvin Engineering 49924 4 páginas. Washing machine taps
Product Installation Guidelines
3. Testing
−
Once temperature indicator is fitted, check the operation of the unit and inspect for any leaks.
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
Handle is loose
SERVICE AND MAINTENANCE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the
jumper valve for wear and damage.
Replace if required.
6. Clean the spindle and body of debris.
7. Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product to re-
assembly method.
© Galvin Engineering Pty Ltd
CAUSE
Jumper valves are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Version 1, 7 October 2022, Page 3 of 4
RECTIFICATION
Replace jumper valve
Refurbish tap seat using a
reseating tool.
Replace o-ring
Turn water on
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Tighten locking ring