Product Installation Guidelines

TROUBLESHOOTING

PROBLEM
Cistern does not flush
NON-SERVICEABLE PRODUCTS INFORMATION
Push Button, Air Pump, Face Plate
These items are non-serviceable products. If damaged, they must be replaced.
If there appears to be any problems with these items, please contact Galvin Engineering.
Note: Before attempting to replace any of these items check that you have access to re-run the
connection leads. If you do not have access or you have any doubts, please contact Galvin Engineering
for advice before commencing replacement.

WARRANTY

The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including
but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer's warranty available for download
from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free
from operational defects in workmanship and materials for the warranty period as shown on the schedule in
the manufacturer's warranty. During the warranty period, Galvin Engineering will replace or repair any
defective products manufactured by Galvin Engineering without charge, so long as the terms of the
Manufacturer's warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy
for breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other
property which is damaged if this product does not work properly, other costs resulting from labour charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions,
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
CAUSE
No air supplied from air pump
Faulty Push Button
Incorrect connections
Version 1, 6
RECTIFICATION
Check air tube for leaks
Replace air pump if damaged
Replace damaged push button
Check all connections