Galvin Engineering CliniMix WM-PMSKIT Manual de instalación del producto - Página 5
Navegue en línea o descargue pdf Manual de instalación del producto para Productos de fontanería Galvin Engineering CliniMix WM-PMSKIT. Galvin Engineering CliniMix WM-PMSKIT 6 páginas. Inwall shower disinfection kit
1
10. Cool down unit
1.
Turn off hot water by rotating hot handle anti-
clockwise.
2.
Turn cold handle clockwise (until handle stops) to
introduce cold water to the system. The cold water
will flush out the hot water, hence cooling the unit.
The handles may heat up during the disinfection
process. The use of protective hand wear is
recommended.
This unit becomes very hot during operation.
Cooling the unit is essential before removing
Version 1, 22 October 2019, Page 5 of 6
2
11. Re-assemble
Ensure enough time is given for the cold water
cooling process of the disinfection unit. Once cool
to the touch the unit can be removed.
First, turn off cold water by rotating disinfection unit
cold handle anti-clockwise.
Remove disinfection unit, by reversing step 7.
Re-assemble shower unit, by reversing steps 5 to 3.
Re-assemble shower outlet by reversing steps 2 & 1.
Turn on the water and check for correct operation.